Click on Series name for product info on aimtec.com Series AM8T-Z 8 Watt DC-DC Converter FEATURES: o o RoHS compliant Operating temperature -40 C to + 85 C 24 Pin DIP Package Continuous Short Circuit Protection Wide 2:1 input range Low ripple and noise Efficiency up to 85% Input/output Isolation voltage 1500VDC Models Single output Input Voltage Output Voltage Output Current Capacitive load Efficiency Model (V) (V) max (mA) ( F) (%) AM8T-1203SZ 9-18 3.3 2000 3300 80 AM8T-1205SZ 9-18 5 1500 2200 82 AM8T-1212SZ 9-18 12 665 470 85 AM8T-1215SZ 9-18 15 535 220 83 AM8T-2403SZ 18-36 3.3 2000 3300 80 AM8T-2405SZ 18-36 5 1500 2200 82 AM8T-2412SZ 18-36 12 665 470 85 AM8T-2415SZ 18-36 15 535 220 84 AM8T-4803SZ 36-72 3.3 2000 3300 80 AM8T-4805SZ 36-72 5 1500 2200 82 AM8T-4812SZ 36-72 12 665 470 84 AM8T-4815SZ 36-72 15 535 220 84 Models Dual output Input Voltage Output Voltage Output Current Capacitive load Efficiency Model (V) (V) max (mA) ( F) (%) AM8T-1205DZ 9-18 5 800 1000 82 AM8T-1212DZ 9-18 12 335 220 84 AM8T-1215DZ 9-18 15 265 100 84 AM8T-2405DZ 18-36 5 800 1000 82 AM8T-2412DZ 18-36 12 335 220 83 AM8T-2415DZ 18-36 15 265 100 85 AM8T-4805DZ 36-72 5 800 1000 82 AM8T-4812DZ 36-72 12 335 220 85 AM8T-4815DZ 36-72 15 265 100 85 Input Specifications Parameters Nominal Typical Maximum Units 12 9-18 VDC Voltage range 24 18-36 48 36-72 Filter (Pi) Network Turn on Transient process time 350 ms Start up time 20 ms 12 Vin -0.7-24 Absolute Maximum Rating 24 Vin -0.7-40 VDC 48 Vin -0.7-100 Peak Input Voltage time 100 ms www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.G 1 of 3 North America only Series AM8T-Z 8 Watt DC-DC Converter Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec 1500 VDC Case/input & Output 1000 VDC Resistance > 1000 MOhm Capacitance 1000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 1 % Voltage balance (Dual output model) Balanced Load 1 % Short Circuit protection Continuous Short Circuit restart Auto recovery Current Limiting 140 % of Iout max Line voltage regulation HL-LL 0.5 % Load voltage regulation 10% to 100% load 0.5 % o Temperature coefficient 0.02 %/ C Rising time 10 ms Ripple and Noise 75 mVp-p General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 330 KHz o Operating temperature With Derating above 55C -40 to +85 C o Storage temperature -40 to +125 C o Max Case temperature +100 C Cooling Free air convection Humidity 95 % Case material Nickel coated cooper Weight 17 g Dimensions (L x H x W) Tolerance 0.5 mm or 0.02 inches 1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm o MTBF >1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency Approval CE nd IEC 60950-1:2005 (2 Edition) EN 60950-1:2006 EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A Standards IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.G 2 of 3 North America only