Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9510 Multi-Conductor - Computer Cable for EIA RS-232 Applications
For more Information
please call
1-800-Belden1
General Description:
24 AWG stranded (7x32) TC conductors, semi-rigid PVC insulation, twisted pairs, overall Beldfoil shield
(100% coverage), 24 AWG stranded TC drain Wire (continued), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
10 24 7x32 TC - Tinned Copper
Total Number of Conductors: 20
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
S-R PVC - Semi-Rigid Polyvinyl Chloride 0.011
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24 7x32 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.034
Overall Cable
Overall Nominal Diameter: 0.368 in.
Pair
Pair Color Code Chart:
Number Color
1 Black & Red
2 Black & White
3 Black & Green
4 Black & Blue
5 Black & Yellow
6 Black & Brown
7 Black & Orange
8 Red & White
9 Red & Green
10 Red & Blue
Mechanical Characteristics (Overall)
Operating Temperature Range: -30C To +80C
Non-UL Temperature Rating: 80C (UL AWM Style 2464)
Bulk Cable Weight: 68 lbs/1000 ft.
Max. Recommended Pulling Tension: 110 lbs.
Min. Bend Radius/Minor Axis: 3.750 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG
CEC/C(UL) Specification: CMG
Page 1 of 3 01-05-2017Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9510 Multi-Conductor - Computer Cable for EIA RS-232 Applications
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 2464 (300 V 80C)
CSA Specification: AWM I A
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 FT4 Loading
C(UL) Flame Test: FT4
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
30
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
50
Nominal Velocity of Propagation:
VP (%)
60
Nom. Conductor DC Resistance:
DCR @ 20C (Ohm/1000 ft)
24
Nominal Outer Shield DC Resistance:
DCR @ 20C (Ohm/1000 ft)
16.5
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
1.1 Amps per conductor @ 25C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
9510 060100 100 FT 7.600 LB CHROME 10 PR #24 PVC FS PVC
9510 0601000 1,000 FT 75.000 LB CHROME C 10 PR #24 PVC FS PVC
9510 0602000 2,000 FT 140.000 LB CHROME C 10 PR #24 PVC FS PVC
9510 060500 500 FT 39.000 LB CHROME C 10 PR #24 PVC FS PVC
9510 0605000 5,000 FT 405.000 LB CHROME C Z 10 PR #24 PVC FS PVC
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 2 Revision Date: 08-31-2012
2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Page 2 of 3 01-05-2017