D3G133-BF05-14 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Voltage 1 Indicates an imminently hazardous situation which will result in death or serious injury if the specified actions are not taken. 1.5 Safety and protective features 2 Compliance with the instructions is imperative. 1.6 Electromagnetic radiation 2 WARNING 1.7 Mechanical movement 2 Indicates a potentially hazardous situation which can result in 1.8 Emissions 2 death or serious injury if the specified actions are not taken. 1.9 Hot surface 2 Exercise extreme caution while working. 1.10 Storage 2 CAUTION 1.11 Disposal 2 Indicates a potentially hazardous situation which can result in minor or moderate injury or damage to property if the specified 2. INTENDED USE 3 actions are not taken. 3. TECHNICAL DATA 4 NOTE A potentially harmful situation can occur and, if not avoided, can 3.1 Product drawing 4 lead to property damage. 3.2 Nominal data 5 3.3 Technical description 5 1.2 Staff qualifications 3.4 Mounting data 5 The device may only be transported, unpacked, installed, operated, maintained and otherwise used by suitably qualified, trained and 3.5 Transport and storage conditions 5 authorized technical staff. 3.6 Electromagnetic compatibility 5 Only authorized specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation. 4. CONNECTION AND STARTUP 6 4.1 Mechanical connection 6 1.3 Basic safety rules 4.2 Electrical connection 6 The safety hazards associated with the device must be assessed again 4.3 Plug connection 6 following installation in the final product. 4.4 Connection diagram 8 Note the following when working on the device: Do not perform any modifications, additions or conversions on the 4.5 Checking connections 9 device without the approval of ebm-papst. 4.6 Switching on the device 9 4.7 Switching off the device 9 1.4 Voltage Check the device s electrical equipment at regular intervals see 5. INTEGRATED PROTECTIVE FEATURES 9 Chapter 6.2 Safety inspection. 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 10 Replace loose connections and defective cables immediately. CAUSES AND REMEDIES DANGER 6.1 Cleaning 10 Electrically charged device 6.2 Safety inspection 10 Risk of electric shock When working on an electrically charged device, stand on a rubber mat. WARNING Live terminals and connections even with device switched off Electric shock Item no. 52960-5-9970 ENU Change 85321 Approved 2015-10-19 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsD3G133-BF05-14 Operating instructions Wait five minutes after disconnecting the voltage at all poles WARNING before opening the device. Rotating device Long hair and dangling items of clothing, jewelry and the like CAUTION can become entangled and be pulled into the device. Injuries In the event of a fault, the rotor and the impeller will be can result. energized Do not wear any loose-fitting or dangling clothing or jewelry The rotor and the impeller have basic insulation. while working on rotating parts. Protect long hair with a cap. Do not touch the rotor and impeller once installed. 1.8 Emissions CAUTION If control voltage or a stored speed set value is applied, WARNING the motor will restart automatically, e.g. after a power Depending on the installation and operating conditions, failure. the sound pressure level may exceed 70 dB(A). Risk of injury Risk of noise-induced hearing loss Keep out of the device danger zone. When working on the Take appropriate technical safety measures. device, switch off the line voltage and ensure that it cannot Protect operating personnel with appropriate safety be switched back on. equipment such as hearing protection. After working on the device, remove any tools or other Also observe the requirements of local agencies. objects from the device. 1.9 Hot surface 1.5 Safety and protective features CAUTION DANGER High temperature on electronics housing Missing protective device and protective device that is Risk of burns not working Without a protective device there is a risk of serious injury, for Ensure sufficient protection against accidental contact. instance if the hands reach or are sucked into the device during Explosion-protected motors are designed for safe operation operation. under normal operating conditions and in the event of a fault. Operate the device only with a fixed protective device and In the event of overload, the motor will shut off to avoid guard grille. The fixed protective device must be able to inadmissibly high temperatures. withstand the kinetic energy of a fan blade that becomes detached at maximum speed. There must not be any gaps 1.10 Storage which it is possible to reach into with the fingers, for Store the device, partially or fully assembled, in a dry and example. The device is a built-in component. As the weatherproof manner in the original packaging in a clean environment. operator, you are responsible for ensuring that the device is Protect the device against environmental effects and dirt until final secured adequately. installation. Stop the device immediately if you notice a missing or We recommend storing the device for no longer than one year in ineffective protective device. order to guarantee trouble-free operation and the longest possible service life. 1.6 Electromagnetic radiation Even devices explicitly intended for outdoor use are to be stored as Interference from electromagnetic radiation is possible, e.g. in conjunction described prior to commissioning. with open- and closed-loop control devices. Maintain the storage temperature, see If impermissible radiation levels occur following installation, appropriate Chapter 3.5 Transport and storage conditions. shielding measures have to be taken by the user. NOTE 1.11 Disposal Electrical or electromagnetic interference after installing Comply with all relevant local requirements and regulations when the device in customer equipment. disposing of the device. Verify that the entire setup is EMC-compliant. 1.7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. Item no. 52960-5-9970 ENU Change 85321 Approved 2015-10-19 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions