3040 page 1 of 2 Particulate Filter 2097, P100 * with Nuisance Level Organic Vapor Relief Issue Date 9/1/09 The 3M Particulate Filter 2097, P100 has been developed with your respiratory needs in mind. Specially designed carbon layers help provide relief against nuisance levels of organic vapors.* The 2097 provides you and your workers: Comfort. 3Ms Advanced Electret Media (AEM) provides a lightweight, easy breathing combination not found in 1 fiberglass containing filters. Versatile protection. The 2097 is well suited for a wide range of 3M Particulate Filter 2097, P100 oil and non-oil based particulate contaminants and can be used as a prefilter for certain chemical Suggested Applications: exposures. Chemical Welding manufacturing Simplicity. The versatility of this Brazing filter reduces your inventory and Undercoating Soldering training requirements. Torch cutting Compatibility. The 2097 can be Metal pouring used with 3Ms wide variety of OSHA substance 2 half and full facepiece designs. specific particle exposures: Exceptional filter efficiency. Lead Passing NIOSHs P-series test Asbestos criteria, the 2097 P100 filter Cadmium provides a minimum 99.97% Arsenic WARNING 3 filter efficiency. 4,4 These filters help protect against certain particles. Methylenedianiline Durability. The unique flexible Misuse may result in sickness or death. Before use, (MDA) the wearer must read and understand User Instructions filter material resists abrasion provided as a part of product packaging. Time use Pharmaceutical and wetting. Filters are flame limitations may apply. For proper use, see package manufacturing instructions, supervisor or call 3M OH&ESD Technical and water resistant. Service in U.S.A., 1-800-243-4630. In Canada, call 1-800-267-4414. 3M recommended for relief against nuisance levels of organic vapors. Nuisance level organic vapor refers * to concentrations not exceeding OSHA PEL or applicable exposure limits, whichever is lower. Do not use for Additional use instructions, respiratory protection against organic vapors. product limitations, approval References: 1. The 2097 filter contains no components made from fiberglass. labels, and warnings are 2. The 2097 filter can be used as a stand-alone filter with 3M 6000, 7000 and Ultimate FX FF-400 Series included with each facepiece Facepieces or as a prefilter with 3M 5000 Series Respirators and 6000 Series Cartridges (use with 502 adapter). 3. Tested against particles approximately 0.3 micron in size (mass median aerodynamic diameter) per 42 CFR 84. and filter package. 3M Particulate Filter 2097, P100 3040 page 2 of 2 with Nuisance Level Organic Vapor Relief* Technologies Use For: Solids such as those from processing minerals, coal, iron ore, cotton, flour and certain other substances. Liquid or oil based particles from sprays that do not also emit harmful vapors. Advanced Electret Media Odor-Removing Filter Material P-Series Filter Metal fumes produced from Advanced electrostatically Carbon layers remove many Featuring Advanced Electret welding, brazing, cutting and charged microfibers make nuisance level odors for greater Media, appropriate for other operations involving breathing easier and cooler. comfort and productivity. prolonged use in both oil- and non-oil-containing environments. heating of metals. Radioactive particulate materials Important Filters Filters such as uranium and plutonium. Before using these filters, you Per Bag Per Case Asbestos. must determine the following: 2 100 Relief from nuisance levels of 1. The type of contaminant(s) organic vapors* below the OSHA for which the respirator is Time Use Limitation PEL or applicable government being selected. If filter becomes damaged, soiled, standards, whichever is lower. or breathing becomes difficult, 2. The concentration level 3M recommended for ozone of contaminant(s). leave the contaminated area and protection up to 10 times the dispose of the filter. If used in 3. Whether the respirator can be OSHA PEL.** environments containing only oil properly fitted on the wearers aerosols, dispose of filter after Do Not Use For: face. Do not use with beards, 40 hours of use or 30 days, Gases and vapors above the other facial hair, or other whichever is first. OSHA PEL, including those conditions that prevent a good present in paint spraying seal between the face and the operations, unless combined with faceseal of the respirator. For more information, please contact: approved chemical cartridges. 4. Before use of these respirators, 3M Occupational Health and a written respiratory protection Sandblasting. Environmental Safety Division program must be implemented, (OH&ESD) Oxygen deficient atmospheres. meeting all the requirements Aerosol concentrations In the U.S., contact: of OSHA 29 CFR 1910.134, Customer Service that exceed: including training, medical 1-800-328-1667 10 times the permissible evaluation and fit testing. Technical Assistance exposure limit (PEL) with 1-800-243-4630 half facepiece, or Website www.3M.com/OccSafety 10 times the PEL with full For other 3M products facepiece qualitatively fit 1-800-3M HELPS tested, or In Canada, contact: 50 times the PEL with full 3M Canada Company, OH&ESD * 3M recommended for relief against nuisance levels facepiece quantitatively P.O. Box 5757 of organic vapors. Nuisance level organic vapor London, Ontario N6A 4T1 fit tested, or refers to concentrations not exceeding OSHA PEL or Customer Care applicable exposure limits, whichever is lower. Do not applicable government 1-800-364-3577 use for respiratory protection against organic vapors. regulations, whichever Technical Assistance (Canada only) **3M recommended for ozone protection up to 10 is lower. 1-800-267-4414 times the OSHA PEL. Not NIOSH approved for ozone. Website www.3M.ca/safety Technical Assistance In Mexico 01-800-712-0646 Occupational Health and Environmental Safety Division 5270-2255, 5270-2119 (Mexico City only) Technical Assistance In Brazil 3M Center, Building 235-2E-91 0800-132333 St. Paul, MN 55144-1000