3M Round, Jacketed, Flat Cable
.050" 28 AWG Stranded, Mass-Term, PVC/PVC 3759 Series
Round construction permits easier routing
28 AWG wire on .050 inch centers permits mass
termination to broad line of IDC connectors
Continuous bond and continuous split/bond allows
for mass termination of IDC connectors
Available in continuous bond (nonsplit) wire for
ease of cable fabrication
Meets external wiring requirements of National
Electrical Code, Article 725 (CL2)
Primary cable is zippable for branching or discrete
terminations
UL recognized for USA and Canadian markets
Visit 3M.com/regs or contact your 3M representative
to find the RoHS compliance status of the 3M part
you are interested in.
Date Modified: April , 201 TS-0070-F
Sheet 1 of 2
Physical
Polyvinyl Chloride (PVC); Color: Black
Jacket Material:
PVC; Color: Gray
Primary Material::
(UL) CL2 75C 28 AWG OR AWM 20267
Marking Standard:
3M NU C AWM II A/B 80C 300V FT1 EU <50V
28 AWG, 7 36 AWG [ 7 0.127 ] Tinned Stranded Copper
Conductors:
Polyester Film
Inner Wrap:
Electrical
USA: N.E.C. 725, CL2 or AWM; 300V Canada: 300V EU: <50V
Voltage Rating:
10
Insulation Resistance: (Primary Cable) >1 x 10 /10 ft [3 m]
Unbalanced Balanced
Characteristic Impedance:
90 133
Capacitance: 16.7 pF/ft [ 54.8 pF/m ] 11.9 pF/ft [ 39.0 pF/m ]
0.13 H/ft [ 0.44 H/m ] 0.21 H/ft [ 0.69 H/m ]
Inductance:
1.50 ns/ft [ 4.92 ns/m ] 1.58 ns/ft [ 5.18 ns/m ]
Propagation Delay:
Velocity of Propagation:68% 64%
Note: Unbalanced is measured between ground-signal-ground conductors.Balanced is measured between conductors within a pair.
Environmental
Temperature Rating: USA: CL2; 75C or AWM; -20C to + 80C Canada: 80C
USA: N.E.C. 725, CL2 Canada: FT1
Flammability Rating:
UL File No.: E118773, Power Limited Circuit Cable: CL2 (or AWM Style 20267)
3M is a trademark of 3M Company.
For technical, sales or ordering information call
Electronics Materials Solutions Division
800-225-5373
Interconnect Solutions
3M Round, Jacketed, Flat Cable
.050" 28 AWG Stranded, Mass-Term, PVC/PVC 3759 Series
Number of 3M Part Diameter A .03 Dimension B
Conductors Number (See Note 2)
09 3759/09 0.26 [ 6.6 ] 0.40 [ 10.2 ]
C
10 3759/10 0.26 [ 6.6 ] 0.45 [ 11.4 ]
14 3759/14 0.27 [ 6.9 ] 0.65 [ 16.5 ]
15 3759/15 0.27 [ 6.9 ] 0.70 [ 17.8 ]
Inch
16 3759/16 0.27 [ 6.9 ] 0.75 [ 19.1 ]
[Imm]
20 3759/20 0.30 [ 7.6 ] 0.95 [ 24.1 ]
Tolerance Unless Noted
24 3759/24 0.33 [ 8.4 ] 1.15 [ 29.2 ]
Inch .0 .00 .000
25 3759/25 0.33 [ 8.4 ] 1.20 [ 30.5 ]
.1 .05 .010
26 3759/26 0.33 [ 8.4 ] 1.25 [ 31.8 ]
[ ] Dimensions for Reference Only
30 3759/30 0.37 [ 9.4 ] 1.45 [ 36.8 ]
34 3759/34 0.37 [ 9.4 ] 1.65 [ 41.9 ]
36 3759/36 0.39 [ 9.9 ] 1.75 [ 44.5 ]
37 3759/37 0.39 [ 9.9 ] 1.80 [ 45.7 ]
40 3759/40 0.39 [ 9.9 ] 1.95 [ 49.5 ]
50 3759/50 0.44 [ 11.2 ] 2.45 [ 62.2 ]
60 3759/60 0.47 [ 11.9 ] 2.95 [ 74.9 ]
64 3759/64 0.50 [ 12.7 ] 3.15 [ 80.0 ]
2.4 Ref.
Notes: [61]
1. Red marking on one edge of primary cable designates wire #1.
2. Dimension B pertains to bonded area only. 1.0 Ref.
Bonded
[25]
Split
A B
Paper
[ Mfgr. Option ]
0.50 Typ
.026 Min [ 0.66 ] Polyester Film
[1.27]
PVC Jacket
PVC Primary Insulation
28 AWG, 7 X 36 AWG [ 7 X 0.127 ]
Tinned Stranded Copper Conductors
Ordering Information
3759/XX XX XX
Blank = Standard
SF = Splice Free
Number of Conductors
(See Table)
Blank = Continuous Split/Bonded Wire (Standard)
SO = Continuously Bonded Wire (No Split)
Note: Available in common lengths of 100 ft/roll or 300 ft/roll (
30 m/roll or 91 m/roll), please specify when ordering.
TS-0070-F
Sheet 2 of 2
3M is a trademark of 3M Company.
For technical, sales or ordering information call
Electronics Materials Solutions Division
800-225-5373
Interconnect Solutions