3 6000 Series Half-Mask Respirators Data Sheet Main Features Gas/vapour The 6000 Series Respirators are used with twin lightweight filters FILTER HAZARD INDUSTRY which are fitted by a simple bayonet attachment system, 6051 A1 Organic Anywhere conventional paints are providing an economical and flexible choice. The respirators can 6055 A2 Vapours used (subject to usage conditions) also be used with the 3M S-200 Supplied-Air System for increased (EN14387:2004) Vehicle manufacture convenience and flexibility. Aircraft manufacture and refur- bishment Lightweight Boat building Flexible system (gas / vapour and / or particulate filters Ink and Dye manufacture and plus Supplied-Air option) use Hypo-allergenic facepiece material Adhesive manufacture and use Easy to use Paint and varnish manufacture Well balanced Resin manufacture and use 3 sizes (6100 - small, 6200 - medium, 6300 - large) Low maintenance Manufacture and Maintenance of 6054 K1 Ammonia Economical refrigeration equipment (EN141:2000) Agrochemicals Applications As 6051 but also: 6057 ABE1 Organic Electrolytic processes (EN141:2000) Vapours, Inor- Particulates Acid cleaning ganic and Metal Pickling Acid Gases Metal Etching FILTER HAZARD INDUSTRY As 6057 and 6054 6059 ABEK1 Organic 5911 P1 R Particulates (Fine Pharmaceutical (EN141:2000) Vapours, Inor- 5925 P2 R Dusts and Mists) Powdered Chemicals ganic Gases, 5935 P3 R Construction, Quarrying Acid gases 2125 P2 R Ceramics and Ammonia 2135 P3 R Refractory Materials 6035 P3 R Foundries, Agriculture 6075 A1 & Organic As 6051 but also: (EN143:2000) Woodworking, Food Industry formaldehyde Vapours and Hospitals and Laboratories (EN141:2000) Formaldehyde 2128 P2 R Particulates and Welding, Paper Industry 2138 P3 R nuisance levels of Brewing, 6096 HgP3 Mercury and Laboratories and particulate appli- (EN143:2000) Organic Vapours Chemical Processing (EN141:2000) particulates cations and Acid Gases Typical Smog, Inks and Dyes 6038 P3 R Particulates, Aluminium (EN143:2000) Hydrogen Fluoride Welding Gas up to 30ppm Agriculture The table above lists the filters and typical industrial and relief from Pharmaceutical applications. Ozone, Organic Vapours and Acid The 6000 Series half masks can be used in a variety of Gases below WEL different filter / product options : Gas and vapour filters - The 6000 Series filters fit directly onto the 6000 Series half masks. Particulate filters - The 2000 Series particulate filters fit directly on to the 6000 Series half masks. The 5911 / 5925 / 5935 particulate filters may be used on their own with platform 603 & retainer 501. Correct Usage A combination of gas / vapour and particulate filters - The 5911 / 5925 / 5935 particulate filters can be used with 6000 The 6000 Series facepieces when fitted with 6000 Series Series gas / vapour filters using retainer 501. gas/vapour filters may be used in concentrations of gases or Note: the 6098 or 6099 filters should not be used with the vapours (types specified by 3M) up to 10 times WEL or 1000 ppm 6000 Series half masks. (5000 ppm for 6055) whichever value is lower (APF = 10)*. Gas/vapour filters should not be used to protect the wearer Supplied-air mode using the 3M S-200 Respirator System against a gas or vapour that has poor warning properties (smell (For information on the Supplied-Air System and applications or taste). please see the 3M S-200 Data Sheet). The 6000 Series facepieces when used in conjunction with the Approvals 5911 filter may be used in concentrations of solid and aqueous aerosols up to 4 times WEL (APF = 4)*. The 3M 6000 Series half masks and 6000/5000/2000 Series filters have been shown to meet the Basic Safety Requirements The 6000 Series facepieces when used in conjunction under Article 10 and 11 B of t he European Community Directive with the 5925, 2125, or 2128 filters may be used in 89/686, and are thus CE-marked. concentrations of particulates up to 10 times WEL (APF = 10)*. Approval body for the facepieces: DANTEST identification number 0200 The 6000 Series facepieces when used in conjunction Body involved in Quality Assurance Assessment: with the 5935, 2135, 6038, 6035, or 2138 may be used in BSI/UL identification number 0086 concentrations of particulates up to 20 times WEL (APF = 20)*. Materials The 6000 Series facepieces when used in conjunction with the Facepiece - Thermoplastic Elastomer 2128 and 2138 may be used to protect against ozone up to 10 Head Harness - Polyester / Cotton Elastic times WEL (APF = 10)* and offer relief from nuisance odours Inhale Valve - Natural Rubber below the WEL. Exhale Valve - Silicone Rubber Gasket - Silicone Rubber The 6000 Series facepieces when used in conjunction with the Filter Body (6000) - Polystyrene 2128 and 2138 may be used to offer relief from acid gases Filter Element (6000) - Activated/Treated Carbon below the WEL. Filter Material (5911 / - Polypropylene 5925 / 5935 and 2000 The 6000 Series facepieces when used with the 6038 filter Series) may be used to protect against Hydrogen Fluoride gas up to Maximum Product Weight: 30ppm and offer relief from Ozone, Organic Vapours and acid - With filters 355 grams gases below WEL. - Without filters 85 grams *WEL - Workplace Exposure Limit. Standards These products have been tested to the relevant European Standards as Cleaning and Storage shown below: 1. Cleaning is recommended after each use. Remove the Facepiece EN140:1998 (6100, 6200, 6300) gas/vapour and/or particulate filters. Filter EN141:2000 (6054, 6057, 6059, 2. Clean the facepiece (excluding filters) with 3M 105 face seal 6075 & 6096) cleaners or by immersing in warm cleaning solution, water temperature not to exceed 50C and scrub with soft brush until clean. Add neutral detergent if necessary. EN14387:2004 (6051, 6055) Do not use cleaners containing lanolin or other oils. EN 143:2000 (2125, 2128, 2135, 3. Rinse in fresh, warm water and air dry in a non- contaminated 2138, 5911, 5925, 5935, 6035, atmosphere. 6038) 4. Respirator components, especially exhalation valve and seat, should be inspected prior to each use. A respirator with any damaged or deteriorated components should be discarded. 5. The cleaned respirator should be stored away from contaminated areas when not in use.