3M Particulate Respirators 8825+ and 8835+ Technical Data Sheet Description The 3M Particulate Respirators 8825+ and 8835+ meet the requirements of European Standard EN 149:2001 + A1:2009, filtering facepiece respirators for use against particles. They provide effective respiratory protection for use in industries where workers will be exposed to solid (dust) particles and/or non-volatile liquid particles. Applications Warnings and Use Limitations These respirators are suitable for use in concentrations of solid (dust) Alw ays be sure that the complete product is: particles and/or non-volatile liquid particles up to the following limits: Suitable for the application EN 149:2001+A1:2009 Maximum use Fitted correctly Product Classification concentration Worn during all periods of exposure 8825+ FFP2 R D 10 x WEL Replaced when necessary. 8835+ FFP3 R D 20 x WEL Proper selection, training, use and appropriate maintenance WEL = Workplace Exposure Limit are essential in order for the product to help protect the Respiratory protection is only effective if it is correctly selected, fitted wearer from certain airborne contaminants. Failure to follow and worn throughout the time when the wearer is exposed to hazards. all instructions on the use of these respiratory protection products and/or failure to properly wear the complete Components and materials product during all periods of exposure may adversely affect The following materials are used in the production of the the wearers health, lead to severe or life threatening illness 3MParticulate Respirators 8825+ and 8835+: or permanent disability. Component Material For suitability and proper use follow local regulations, refer to Straps (blue for FFP2 and red Cotton / Polyisoprene / all information supplied or contact a safety professional/3M forFFP3) Polypropylene representative. Tension adjustable buckles Polypropylene Before use, the wearer must be trained in use of the complete Filter / Inner Shell Polypropylene / Polyester product in accordance with applicable Health and Safety Cool Flow Valve Polypropylene / Polyisoprene standards/guidance. Face seal (can be Thermoplastic elastomer (TPE) These products do not protect against gases/vapours. hygienicallycleaned) These products do not contain components made from natural rubber latex, PVC and metals. Do not use in atmospheres containing less than 19.5% oxygen. (3M definition. Individual countries may apply their own limits Product Typical weight on oxygen deficiency. Seek advice if in doubt). 3M Particulate Do not use for respiratory protection against atmospheric 35g Respirator 8825+ contaminants/concentrations which are unknown or immediately dangerous to life and health (IDLH). Do not use with beards or other facial hair that may inhibit 3M Particulate 40g contact between the face and the product thus preventing Respirator 8835+ a good seal. Leave the contaminated area immediately if: Storage and Transportation Breathing becomes difficult. 3M Particulate Respirators 8825+ and 8835+ have a shelf life of Dizziness or other distress occurs. 5 years from date of manufacture. End of shelf life is marked on the product packaging and upon the product headband. Before initial D iscard and replace the respirator if it becomes damaged, use, always check that the product is within the stated shelf life (use or if breathing resistance becomes excessive. by date). Product should be stored in clean, dry conditions within Never alter, modify or repair this device. the temperature range: 20C to + 25C with a maximum relative humidity of <80%. When storing or transporting this product use Before initial use, always check that the product is within original packaging provided. the stated shelf life (use by date). Version: 1 This version is the sole document applicable to the product(s) since its date of publication 3M Personal Safety Division 3M Particulate Respirators 8825+ and 8835+ If you CANNOT achieve a proper fit DO NOT enter the hazardous Fitting Instructions area. See your supervisor. See Figure 1. Users should be fit tested in accordance with national requirements. Before fitting device, ensure hands are clean. For information regarding fit testing procedures, please contact 3M. All respirator components should be inspected for damage prior to each use. Cleaning Instructions 1. Thread top elastic strap through top buckles. Repeat for If the respirator is to be used for more than one shift the face seal/ bottom strap and buckles. gasket must be cleaned at the end of each shift using a 3M Face Seal Wipe 105. 2. Hold respirator under chin, with nosepiece up. DO NOT immerse product in water. 3. Locate the upper strap across the crown of the head and Store cleaned respirator in a clean container to protect it from the lower strap below the ears. Straps must not be twisted. contamination. 4. Adjust tension: Increase - pull evenly on both ends of the Disposal top/bottom straps. Contaminated products should be disposed as hazardous waste 5. Adjust tension: Decrease - without removing respirator, in accordance with national regulations. push out on the back of the buckles. Marking 6. Ensure face seal is properly formed around the nose. R = Reusable 7. The face seal must not be folded in. 8. The seal of the respirator on the face should be fit-checked D = Meets the clogging requirements before entering the workplace. End of Shelf Life. Date format: YYYY/MM/DD Figure 1 Temperature Range Maximum Relative Humidity 1 2 3 4A Name and address of Legal Manufacturer Dispose of in accordance with local regulations Approvals 4B 5A 5B 6 These products meet the requirements of the European Community Directive 89/686/EEC (Personal Protective Equipment Directive) and are thus CE marked. Certification under Article 10, EC Type- Fit Check Examination, has been issued for these products by INSPEC 1. Cover the front of the respirator with both hands being careful International Limited, 56 Leslie Hough Way, Salford, Greater not to disturb the fit of the respirator. Manchester M6 6AJ, UK (Notified Body number 0194). Certification under Article 11, EC quality control, has been issued by BSI (Notified 2. VALVED respirator - INHALE sharply. Body number 0086). 3. If the air leaks around the nosepiece, re-adjust the respirator Made in UK, in an ISO 9001:2008, ISO 14001:2004 and OHSAS and face seal upon the face to eliminate leakage. Repeat the 18001:2007 certified plant. fit check. 4. If air leaks at the respirator edges, adjust the tension of the straps to eliminate the leakage. Repeat the above fit check. Important Notice The use of the 3M product described within this document assumes that the user has previous experience of this type of product and that it will be used by a competent professional. Before any use of this product it is recommended to complete some trials to validate the performance of the product within its expected application. All information and specification details contained within this document are inherent to this specific 3M product and would not be applied to other products or environment. Any action or usage of this product made in violation of this document is at the risk of the user. Compliance to the information and specification relative to the 3M product contained within this document does not exempt the user from compliance with additional guidelines (safety rules, procedures). Compliance to operational requirements especially in respect to the environment and usage of tools with this product must be observed. The 3M group (which cannot verify or control those elements) would not be held responsible for the consequences of any violation of these rules which remain external to its decision and control. Warranty conditions for 3M products are determined with the sales contract documents and with the mandatory and applicable clause, excluding any other warranty or compensation. Personal Safety Division 3M United Kingdom PLC 3M Centre 3M is a trademark of the Cain Road, Bracknell 3M Ireland Limited 3M company. Used under licence Berkshire RG12 8HT Iveagh Building, The Park by 3M subsidiaries and affiliates. Dublin, Ireland 0870 60 800 60 3M 2016. All rights reserved. www.3M.co.uk/safety 1 800 320 500 J335503 Version: 1 This version is the sole document applicable to the product(s) since its date of publication