3M Pleated Foil Shielded Cable
.025" 30 AWG Solid, TPE Primary, PVC Jacket 90101 Series
Compatible with IDC mass termination connectors
Functions with applications requiring standard
impedance of 100 balanced (differential)
Solid pleated copper foil provides flexibility and
35 db average shielding effectiveness
CL2 rated, rugged design and high reliability for
peripheral applications
See the Regulatory Information Appendix (RIA) in
the RoHS compliance section of
www.3Mconnectors.com for compliance information
(RIA E1 & C1 apply)
Date Modified: September 3, 2013 TS-0285-D
Sheet 1 of 2
Physical
Jacket:
Material: Polyvinyl Chloride (PVC)
Color: Gray
Primary Material: Thermoplastic Elastomer (TPE)
Marking:
Standard:
(UL) CL2 75C 30 AWG 3M NU C AWM IIA/B 80C 150V FT1 EU <50V
Conductors: 30 AWG [ 0.254 ] Tinned Solid Copper
Shielding: Solid, Pleated, Copper Foil
Electrical
Voltage Rating: USA: N.E.C. 725, CL2 Canada: 150V EU: <50V
10
Insulation Resistance: (Primary Cable) > 1 10 /10 ft. [ 3 m ]
Unbalanced Balanced
Characteristic Impedance:
53 104
Capacitance: 28.4 pF/ft [ 93.2 pF/m ] 14.5 pF/ft [ 47.6 pF/m ]
Inductance: 0.08 H/ft [ 0.26 H/m ] 0.16 H/ft [ 0.52 H/m ]
Propagation Delay: 1.52 ns/ft [ 4.99 ns/m ] 1.51 ns/ft [ 4.95 ns/m ]
Velocity of Propagation:67% 67%
Note: Unbalanced is measured between ground-signal-ground conductors with shield grounded. Balanced is measured between signal conductors within a pair with the shield floating.
Environmental
Temperature Rating: USA: CL2: 75C Canada: 80C
Flammability Rating: USA: N.E.C. 725, CL2 Canada: FT1
UL File No.: E118773, Power Limited Circuit Cable: CL2
3M is a trademark of 3M Company.
3
Interconnect Solutions For technical, sales or ordering information call
3M Pleated Foil Shielded Cable
.025" 30 AWG Solid, TPE Primary, PVC Jacket 90101 Series
Number of
3M Part Number Dimension A Dimension B
Conductors
20 90101/20 0.60 [ 15.2 ] 0.475 .006 [ 12.07 ]
26 90101/26 0.75 [ 19.1 ] 0.625 .006 [ 15.88 ]
36 90101/36 1.00 [ 25.4 ] 0.875 .009 [ 22.23 ]
40 90101/40 1.10 [ 27.9 ] 0.975 .009 [ 24.77 ]
50 90101/50 1.35 [ 34.3 ] 1.225 .009 [ 31.12 ]
68 90101/68 1.80 [ 45.7 ] 1.675 .012 [ 42.55 ]
80 90101/80 2.10 [ 53.3 ] 1.975 .015 [ 50.17 ]
100 90101/100 2.60 [ 66.0 ] 2.475 .017 [ 62.87 ]
A
B
.025 .002 Typ
[ 0.64 ]
.10 .03
[ 2.5 ]
TPE Primary .026 (0.66) Min
30 AWG [ 0.254 ]
Insulation PVC Jacket
Tinned Solid Copper
Conductors
Paper .005 [ 0.13 ] Pleated Foil Shield
with Adhesive Backing using Solid
(Mfgr. Option)
Copper Foil .001 [ 0.03 ] Thick
Inch
[mm]
Tolerance Unless Noted
.0 .00 .000
Inch .1 .05 .010
[ ] Dimensions for Reference Only
Note: Blue marking on edge of primary cable designates wire #1.
Ordering Information
90101/XX XX
Number of Conductors
Blank = Standard
(See Table)
SF = Splice Free
Note: Standard lengths are 100 ft, 150 ft, and 300 ft rolls. TS-0285-D
Sheet 2 of 2
Please specify when ordering.
3M is a trademark of 3M Company.
3
Interconnect Solutions For technical, sales or ordering information call