8 7 6 5 4 3 2 1
NOTES
TM
1.
REGULATORY INFORMATION:
3M SHIELDED CONTROLLED IMPEDANCE (SCI)
ROHS COMPLIANT. SEE THE
2 ROW CARRIER HOUSING
REGULATORY INFORMATION
.100" ASSEMBLY HARDWARE
APPENDIX (RIA) IN THE
* CARRIERS AVAILABLE IN 3M .100" X .100"
ROHS COMPLIANC SECTION
(2.54MM X 2.54MM) SOCKET.
OF WWW.3MCONNECTORS.COM FOR
COMPLIANCE INFORMATION.
* COMPATIBLE WITH ALL 3M .100" X .100"
2 IN THE EVENT OF CONFLICT
(2.54MM X 2.54MM) HEADERS.
BETWEEN THIS DATA AND THAT
* AVAILABLE IN SHORT OR LONG LATCH STYLES. CONTAINED IN THE PRODUCT
D D
CHECK STYLE FOR MATCH. SPECIFICATION, THE PRODUCT
SPECIFICATION TAKES PRECEDENT.
3 X 7 CARRIER HOUSING
* INTEGRAL LOCKING FEATURE.
* INCLUDES TWO RETENTION CLIPS.
OPTIONAL
CENTERBUMP
PIN STRIP LATCH
* AVAILABLE FOR THE RIGHT ANGLE SCI CONNECTOR.
* RoHS COMPLIANT
GROUND ROW
SIGNAL ROW
98XX-PSMO
NORMALM RETENTION STYLE
2
PHYSICAL:
INSULATION MATERIAL:
2 ROW CARRIER: POLYCARBONATE
3 X 7 CARRIER: GLASS REINFORCED POLYESTER
RETAINER IS FLIPPED
COLOR: BLACK
C C
180 END TO END
FLAMMABILITY: UL 94V-0
MARKINGS: 3M LOGO
CONTACTS: COPPER ALLOY
OPTIONAL
CENTERBUMP
.100 SCI CONNECTOR
GROUND ROW
SIGNAL ROW
CARRIER VERSION
TYPE 24
98XX-PSMR
(SEE TECH SHEET TS-0803)
REVERSEM RETENTION STYLE
B B
B 44714 JAN 03,2013 JNC RS
REVISED AND REDRAWN
DESIGN REFERENCE NEXT ASSEMBLY REV ECO ISSUE DATE AND DESCRIPTION DRFT CHKD
DISTRIBUTION DRFT DATE MFG DATE
CODES CASTIGLIONE JAN 03,2013
CHKD DATE APPVL DATE
R. SCHERER JAN 03,2013
NOTE:
A A
DIVISION DIVISION CODE
C 3M COPYRIGHT 2013
1) PIN STRIP LATCH IS FOR USE WITH
3M Center
Interconnect Solutions ISD
This document and the information it contains are
3M property and may not be reproduced or further
St. Paul,
.100 SCI, RIGHT ANGLE CONNECTOR
SCALE TOLERANCES
DO NOT distributed without 3M permission, or used or
MN 55144
EXCEPT AS disclosed other than for 3M authorized purposes.
SCALE
TYPE 22 ONLY.
All rights reserved.
NOTED
DRAWING
TITLE
(SEE TECH SHEET TS-0803)
INCHES
2 ROW CARRIER
3M ELECTRONIC SOLUTIONS DIVISION
.0
.00 .01
INTERCONNECT SOLUTIONS
ASSEMBLY HARDWARE,
.000 .005
8 7 6 5 4 3 2 1
NOTES
TM
1 POLARIZING GROOVE OMITTED FOR
3M SHIELDED CONTROLLED IMPEDANCE (SCI)
POSITIONS 6 AND 8.
.100" ASSEMBLY HARDWARE
2 POLARIZING GROOVE OMITTED FOR
POSITIONS 6, 8, 10, 12 AND 14.
3 THE NORMALM RETENTION STYLE
+.000
IS ILLUSTRATED. FOR THE REVERSE
DIM. SEE TABLE 1
-.008M RETENTION STYLE THE CABLE
ASSEMBLY RETAINER IS FLIPPED 180
.00
.559
DIM.
END TO END AND THESIGNA
-.20
D D
LOCKING WEDGE
ANDGROUN ROWS OF CONTACTS
14.20
ARE ALSO REVERSED.
LOCKSRELEASE LATC
LONG
+.000 IN CLOSED POSITION
OPTIONAL LOCKING WEDGE
4
LATCH
DIM. SEE TABLE 1
-.008 PREVENTS SCI REMOVAL.
25 POSITION (CUT TO LENGTH)
.00
DIM.
5 RELEASE LATCH CAN BE MOVED
-.20
LONG LATCH CARRIER
A
WITH FINGERNAIL TO ALLOW
REPLACEMENT OF SCI CABLE
LINE.
CABLE ASSEMBLY RETAINER
SEE NOTE 3
.711
2X .421
18.05
CARRIER BOTTOM HALF
10.70
SHORT
LATCH
TABLE 1: CARRIER POSITIONS
C C
A
CONTACT QTY. DIM. DIM. DIM. DIM.
.240
06 .20 [5.08] .41 [10.48] .32 [8.22] .46 [11.68]
+.000
6.10
08 .30 [7.62] .51 [13.02] .42 [10.76] .56 [14.22]
DIM. SEE TABLE 1
-.008
10 .40 [10.16] .61 [15.56] .52 [13.30] .66 [16.76]
*
12 .50 [12.70] .71 [18.10] .62 [15.84] .76 [19.30]
.00
DIM.
14 .60 [15.24] .81 [20.64] .72 [18.38] .86 [21.84]
-.20
*
16 .70 [17.78] .91 [23.18] .82 [20.92] .96 [24.38]
*
20 .90 [22.86] 1.11 [28.26] 1.02 [26.00] 1.16 [29.46]
*
26 1.20 [30.48] 1.41 [35.88] 1.32 [33.62] 1.46 [37.08]
*
30 1.40 [35.56] 1.61 [40.96] 1.52 [38.70] 1.66 [42.16]
34 1.60 [40.64] 1.81 [46.04] 1.72 [43.78] 1.86 [47.24]
*
40 1.90 [48.26] 2.11 [53.66] 2.02 [51.40] 2.16 [54.86]
*
.004
DIM. SEE TABLE 1
50 2.40 [60.96] 2.61 [66.36] 2.52 [64.10] 2.66 [67.56]
*
DIM. .10
60 2.90 [73.66] 3.11 [79.06] 3.02 [76.80] 3.16 [80.26]
64 3.10 [78.74] 3.31 [84.14] 3.22 [81.88] 3.36 [85.34]
*
.100 TYP.
* TOOLED POSITIONS: CONTACT 3M SALES FOR ADDITIONAL POSITIONS
2.54
ROW OF GROUND CONTACTS
(SEE NOTE 3)
B B
.100 2.54
ROW OF SIGNAL CONTACTS
(SEE NOTE 3)
.14 3.5
SEE NOTE 1
CENTERBUMP
SEE NOTE 2
ASSEMBLY OF
(OPTIONAL)
LOCKING WEDGE
SEE NOTE 4
CABLE ASSEMBLY
ORDERING INFORMATION
RELEASE LATCH
B 44714 JAN 03,2013 JNC RS
SEE NOTE 5
2 ROW CARRIER HOUSING
REVISED AND REDRAWN
DESIGN REFERENCE NEXT ASSEMBLY REV ECO ISSUE DATE AND DESCRIPTION DRFT CHKD
DISTRIBUTION DRFT DATE MFG DATE
CODES CASTIGLIONE JAN 03,2013
98XX-XXXX
CHKD DATE APPVL DATE
R. SCHERER JAN 03,2013
A A
DIVISION DIVISION CODE
C 3M COPYRIGHT 2013
3M Center
Interconnect Solutions ISD
This document and the information it contains are
MOLDED RETENTION FEATURE:
CONTACT QTY.
3M property and may not be reproduced or further
St. Paul,
SCALE TOLERANCES
DO NOT distributed without 3M permission, or used or
MO = NORMAL
SEE TABLE 1 MN 55144
EXCEPT AS disclosed other than for 3M authorized purposes.
SCALE
All rights reserved.
NOTED
MR = REVERSE
DRAWING
TITLE
INCHES
CARRIER STYLE:
.0
.00 .01
PS = CENTERBUMP, SHORT LATCHES
ASSEMBLY HARDWARE,
.000 .005
A-A
SECTION
NS = NO CENTERBUMP, SHORT LATCHES
THIRD ANGLE PROJECTION .0000
.100 SCI CARRIER
PL = CENTERBUMP, LONG LATCHES
MILLIMETERS
INTERPRET PER
ASME Y14.5 - 1994
0
NL = NO CENTERBUMP, LONG LATCHES
.0 .3
CAGE SIZE DRAWING NO. REV.
MAX SURFACE ROUGHNESS
.00 .13
NUMBER
ALL SURFACES .000 78-5100-0802-8 B
MODEL DET.
MARKED ONLY
ANGLES
YES NO SHT 2 OF 3
LISTS
8 7 6 5 4 3 2 1
78-5100-0802-8 B