8 7 6 5 4 3 2 1 TM 3M 100G QSFP28 DIRECT ATTACH COPPER CABLE ASSEMBLIES, 9Q SERIES 50 0.10 7 D D 50 0.10 TOP SIDE POS. 38 POS. 19 POS. 20 POS. 1 DIM. POS. 20 POS. 19 18.75 POS. 38 POS. 1 3 5 P2 P1 91 38 1 11.3 C C DIM. 8.50 6 4 2 19.0 OPTIONAL ACETATE TAPE/HST LOW PROFILE CABLE DEPEND ON CABLE SIZE 72.0 CABLE LENGTH (METER) REFER TO P/N TABLE WIRING LIST P1 END P2 END POS SIGNAL POS SIGNAL 1 GND (TX) 20 GND (RX) 2 TX2n 21 RX2n B B 3 TX2P 22 RX2p 4 GND (TX) 23 GND (RX) 5 TX4n 24 RX4n 6 TX4P 25 RX4p 9QXX-114-XX-X.XX 7 GND (TX) 26 GND (RX) WWYY - SN:XXXXXXXX 13 GND (RX) 32 GND (TX) 14 RX3p 33 TX3p 15 RX3n 34 TX3n 16 GND (RX) 35 GND (TX) STANDARD PRODUCT LABEL DESCRIPTION 17 RX1p 36 TX1p (CUSTOM AVAILABLE UPON REQUEST) 18 RX1n 37 TX1n C 86392 SEP 26,2019 JNC DLD 19 GND (RX) 38 GND (TX) REVISE NOTES 20 GND (RX) 1 GND (TX) B 84769 JUL 17,2019 JNC DLD LOW SPEED SIGNALS ADDED CL2 CABLE 21 RX2n 2 TX2n P1 & P2 OPTIONS 22 RX2p 3 TX2P POS SIGNAL A 74404 JUN 22,2017 YL YL 23 GND (RX) 4 GND (TX) NEW RELEASE 8 ModSelL DESIGN REFERENCE NEXT ASSEMBLY REV ECO ISSUE DATE AND DESCRIPTION DRFT CHKD 24 RX4n 5 TX4n 9 ResetL ACCESS DRFT DATE MFG DATE CODES YUNLONG MAR 02,2017 E. CHEN MAR 02,2017 25 RX4p 6 TX4P CHKD DATE APPVL DATE 10 VccRx YUNLONG MAR 02,2017 S. BANDHU MAR 02,2017 A A 26 GND (RX) 7 GND (TX) DIVISION DIVISION CODE C 3M COPYRIGHT 2019 11 SCL 3M Center EMSD This document and the information it contains are 32 GND (TX) 13 GND (RX) 3M property and may not be reproduced or further St. Paul, SCALE TOLERANCES DO NOT distributed without 3M permission, or used or 7 PRODUCT LABEL 2 12 SDA EXCEPT AS MN 55144 disclosed other than for 3M authorized purposes. 2 SCALE 33 TX3p 14 RX3p All rights reserved. TM NOTED 3M LOW PROFILE TWIN AXIAL 1 DRAWING 27 ModPrsL 6 4 TITLE INCHES 34 TX3n 15 RX3n CABLE 3M ELECTRONICS MATERIALS SOLUTIONS DIVISION .0 28 IntL 100G QSFP28 DIRECT 5 RIVET 2 .00 35 GND (TX) 16 GND (RX) INTERCONNECT SOLUTIONS .000 4 PADDLE CARD 2 29 VccTx 8 7 6 5 4 3 2 1 TM 3M 100G QSFP28 DIRECT ATTACH COPPER CABLE ASSEMBLIES, 9Q SERIES TABLE 1 NOTES: 1. ORDERING INFORMATION: 9QXX-114-XX-X.XX LENGTH B C ASSEMBLY LENGTH X IN METERS SEE TABLE 1 ASSY CABLE ORDERING INFORMATION TOLERANCE NOMINAL NOMINAL D LENGTH(m) SIZE D (mm) (mm) (mm) EEPROM MEMORY MAP 22= IEEE Std 802.3bj-2014 100GBASE-CR4 XX= CUSTOMIZATION(SEE 3M SALES REP) 9QJ0-114-22-0.50 0.50 30AWG +10/-0 9QJ0-114-22-1.00 1.00 30AWG (2.8) (15.0) AWG 0= 30AWG (only for below and 2 meters) 9QJ0-114-22-2.00 2.00 30AWG 6= 26AWG (only for 2 meters and above) 9QH6-114-22-2.00 2.00 26AWG +50/-0 CABLE TYPE 9QH6-114-22-3.00 3.00 26AWG (3.8) (16.0) J= 30AWG UTJ PVC JACKET WITH SHIELD (UP TO 2 METERS) N= 30AWG CL2 JACKET WITH SHIELD (UP TO 2 METERS) 9QH6-114-22-4.00 4.00 26AWG H= 26AWG UTJ PVC JACKET WITH SHIELD (2 TO 4.5 METERS) 30AWG M= 26 AWG CL2 JACKET WITH SHIELD (2 TO 4.5 METERS) 9QN0-114-22-1.00 1.00 (3.5) (17.8) CL2 2. REFER TO TABLE 1 FOR CABLE LENGTH, WIDTH, THICKNESS AND WIRE AWG +50/0 26AWG 9QM6-114-22-3.00 3.00 (6.0) (18.5) 3. PCB PINOUT DESIGNED TO SFF8436 SPECIFICATION CL2 4. CABLE ASSEMBLY DESIGNED TO SFF 8661 & IEEE 802.3bj SPECIFICATION 5. JACKET FOR CABLE TYPE J AND H: PVC, COLOR: BLACK C C * JACKET FOR CABLE TYPE N AND M: HALOGEN-FREE CL2, COLOR: BLACK Regulatory: For regulatory information about this product, visit 3M.com/regs or contact your 3M representative. METAL SHELL: NICKEL PLATED ZINC ALLOY * PULL TAB: HALOGEN-FREE THERMOPLASTIC, COLOR: BLACK Technical Information: The technical information, recommendations and other PCB FOR CABLE TYPE J AND H: HALOGENATED FLAME RETARDENT * statements contained in this document are based upon tests or experience that PCB FOR CABLE TYPE N AND M: HALOGEN-FREE FLAME RETARDENT 3M believes are reliable, but the accuracy or completeness of such information * ASSEMBLIES WITH CABLE TYPE N AND M ARE FULLY HALOGEN-FREE is not guaranteed. 6. UNLESS OTHERWISE NOTED,REFERENCES TO INDUSTRY SPECIFICATIONS ARE INTENDED Product Use: Many factors beyond 3M s control and uniquely within user s control TO INDICATE SUBSTANTIAL COMPLIANCE TO THE MATERIAL ELEMENTS OF THE can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance of a SPECIFICATION. SUCH REFERENCES SHOULD NOT BE CONTRUED AS A GUARANTEE 3M product, user is solely responsible for evaluating the 3M product and OF COMPLIANCE TO ALL REQUIREMENTS IN A GIVEN SPECIFICATION. determining whether it is fit for a particular purpose and suitable for user s method of application. 7. PRODUCT SPECIFICATION REFER TO 3M DOCUMENT: 78-5102-0262-1 Warranty, Limited Remedy, and Disclaimer: Unless an additional warranty is 8. CABLE RETURN LOSS PERFORMANCE IS VALID FOR CABLE ASSEMBLIES specifically stated on the applicable 3M product packaging or product literature, OF A MINIMUM OF 1.00 METER IN LENGTH. CABLE ASSEMBLIES LESS 3M warrants that each 3M product meets the applicable 3M product specification at THAN 1.00 METER IN LENGTH MAY NOT ACHIEVE THE RETURN LOSS the time 3M ships the product. 3M MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR PERFORMANCE IN IEEE802.3bj. CABLE RETURN LOSS PERFORMANCE CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED IS SUBJECT TO CHANGE WITH DIFFERENT CABLE ASSEMBLY LENGTHS. WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OR TRADE. END USER WILL NEED TO DETERMINE WHETHER THIS PRODUCT IS If the 3M product does not conform to this warranty, then the sole and exclusive SUITABLE FOR THEIR INTENDED APPLICATION. remedy is, at 3M s option, replacement of the 3M product or refund of the purchase price. B B 9. FOR CUSTOM LENGTHS CONTACT A 3M SALES REPRESENTATIVE Limitation of Liability: Except where prohibited by law, 3M will not be liable for * 10 HOLGEN-FREE IS DEFINED AS BOTH (1) NO HALOGEN COMPOUNDS ARE any loss or damage arising from the 3M product, whether direct, indirect, special, INTENTIONALLY ADDED TO THE PRODUCT OR USED IN THE MANUFACTURING incidental or consequential, regardless of the legal theory asserted, including PROCESS FOR THE PRODUCT, AND (2) ANY IMPURITIES PRESENT ARE LESS warranty, contract, negligence or strict liability. THAN 900 PPM BROMINE, LESS THAN 900 PPM CHLORINE, AND/OR LESS THAN 1500 PPM TOTAL BROMINE AND CHLORINE. 3M Business Center Electronics Materials Solutions Division 13011 McCallen Pass, Bldg. C Austin, TX 78753-5380 1-800-225-5373 www.3M.com/interconnect C 86392 SEP 26,2019 JNC DLD REVISE NOTES B 84769 JUL 17,2019 JNC DLD ADDED CL2 CABLE OPTIONS A 74404 JUN 22,2017 YL YL NEW RELEASE DESIGN REFERENCE NEXT ASSEMBLY REV ECO ISSUE DATE AND DESCRIPTION DRFT CHKD ACCESS DRFT DATE MFG DATE CODES YUNLONG MAR 02,2017 E. CHEN MAR 02,2017 CHKD DATE APPVL DATE YUNLONG MAR 02,2017 S. BANDHU MAR 02,2017 A A DIVISION DIVISION CODE C 3M COPYRIGHT 2019 3M Center EMSD This document and the information it contains are 3M property and may not be reproduced or further St. Paul, SCALE TOLERANCES DO NOT distributed without 3M permission, or used or EXCEPT AS MN 55144 disclosed other than for 3M authorized purposes. 2 SCALE All rights reserved. NOTED 1 DRAWING TITLE INCHES .0 3M ELECTRONICS MATERIALS SOLUTIONS DIVISION 100G QSFP28 DIRECT .00 INTERCONNECT SOLUTIONS .000 ATTACH COPPER CABLE THIRD ANGLE PROJECTION .0000