1.20 (30,5) Data Sheet DBR6 Direct Bury Splice Kit 600 Volts Application Engineering Specification: Use part DBR6, which includes a Scotchlok R electrical The device, 3M Brand DBR6 Direct Bury Splice Kit, shall spring connector, to electrically connect two or more splice and effectively moisture seal two or more conductors. prestripped copper wire ends in a pigtail application and The electrical connector shall be a Scotchlok R. The moisture seal the connection for direct burial. device shall be installed per manufactures instructions and all applicable codes. The device shall be UL Listed as a Wire Wire Connector System For Use With Underground Conductors. Common AWG wire combinations (copper wire only, solid or stranded). Construction: 2 3 10 1 10 to 1 12 2 4 12 1 12 to 1 3 14 Connector: Steel spring, metal shell, 3 4 14 1 12 to 2 3 16 flame retardant pvc insulator 4 6 16 1 14 to 2 3 16 Tube: Polypropylene See page two for complete table of UL Listed combinations. Gel: Silicone electrical insulating gel Regulatory Agencies: Application Data: UL Listed as a Wire Connector System For Use With Application Temperature: 32F to 120F Underground Conductors. (0C to 49C) UL File No. E102356 Operating Temperature: 221F to 40F Tested per UL Standard 486D (105C to 40C) Voltage Rating: 600 Volts CSA Certified as a Underground Cable Splicing Kit CSA File No. LR91920 Weight of one kit ( 2 splices ): .0990 lbs Tested per CSA Standard C22.2 No.198.2. (44,94 gm) Storage: Do not store above 120F (49C ) Not for use in direct ultraviolet exposure. inch .58 (mm) (14,7 4.2 ) (106,6) 5/8 INCH STRIP LENGTH GUIDE 1.1 (27,9)DBR6 Instruction 5/8 inch For Use: (15,9mm) WIRE COMBINATIONS 1 AWG CU TO CU ONLY EXAMPLE 1 HOW TO READ THIS CHART 2 EXAMPLE 1: 5 No 18 sol + 2 No 18 sol EXAMPLE 2: 1 No 10 str + 2 No 12 sol EXAMPLE 2 34 5 All wire combinations are 600 volt UL Listed when using insulation thickness such as TW and THHN. METRIC WIRE COMBINATIONS Conductor Combinations Cross Section Capacity Minimum Maximum Quantity Size Type 2 2 2 5,0mm 16,0mm 5 1,0mm sol/str 2 4 1,5mm sol/str Copper conductors only 2 2 2,5mm sol/str Not UL Listed or 2 2 4,0mm sol/str CSA Certified IMPORTANT NOTICE TO PURCHASER: All statements or recommendations of the SELLER SHALL NOT BE LIABLE TO THE All statements, technical information and seller which are not contained in the Sellers USER OR ANY OTHER PERSON UNDER recommendations related to the Sellers current publications shall have no force or ANY LEGAL THEORY, INCLUDING BUT NOT products are based on information believed effect unless contained in an agreement LIMITED TO NEGLIGENCE OR STRICT to be reliable, but the accuracy or signed by an authorized officer of the Seller. LIABILITY, FOR ANY INJURY OR FOR ANY completeness thereof is is not guaranteed. The statements contained herein are made in DIRECT OR CONSEQUENTIAL DAMAGES Before utilizing the product, the user should lieu of all warranties express or implied, SUSTAINED OR INCURRED BY REASON determine the suitability of the product for its including but not limited to the implied OF THE USE OF ANY OF THE SELLERS intended use. The user assumes all risks and warranties of merchantability and fitness for a PRODUCTS. liability whatsoever in connection with such particular purpose which warranties are use. hereby expressly disclaimed. 3M 1991 3M Division 11 / 1 / 91 6801 River Place Blvd. Austin, TX 787269000