W W Highland Terminals D L FDI14-187, FDI18-187 Female Disconnect, Nylon Fully Insulated, Butted Seam Data Sheet Wire Maximum Product Range Mates with Male Tab Barrel Barrel Insulation Number (AWG) W idth (W)Lx Thickness WD Length I.D. Diameter F4DI14-187106-101.187 x 0.02 00.803.305.205.205.08 0.14 F8DI18-187202-101.187 x 0.02 00.803.305.205.205.08 0.14 Installation Information WARNING UNDERWRITERS CANADIAN STANDARDS Turn power off before installing or removing terminal. All electrical LABORATORIES ASSOCIATION work should be done according to appropriate electrical codes. STANDARD NO. UL 310 STANDARD NO. 22.2 3M FILE NO. E70512 NO. 153 UL Listed and CSA Certified for use on stranded copper 3M FILE NO. LR22190 (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Make the crimp in the proper station of a recommended 3M crimp tool: TH-440, TH-450 (scissor style), or Specifications TR-490 (ratchet style) hand tools. Wire Size: See Table Above Barrel Seam: Butted Insulator Max. Volt Rating: 600 V Building Wire 1000 V Signs or Fixtures (Luminaires) Barrel Crimp (Electrical) Maximum Operating Temp: 221F (105C) Maximum Current: Same as Wire Insulator Material: Nylon Terminal Material: Brass Plating: Tin Suitable for factory installation on steel or brass tabs. UL and CSA. Suitable for field application on brass tabs, strain relief is required. UL only.Engineering Specification Crimp-Type Female Disconnects shall, electrically and The Nylon Fully Insulated 0.187 Female Disconnect mechanically, connect permanently to the prestripped shall be tin plated 0.016 thick brass, with a tongue for end of a stranded copper wire: and have a tongue gripping a 0.187 x 0.020 Male Tab, per ANSI/NEMA portion with fingers which grip a Male Quick Slide in a CD-2 and a 0.250 long barrel covered by a molded separable, reusable manner, forming a Quick Connect nylon funnel entry sleeve, which extends to cover the Wiring Termination. tongue, color coded and sized for a specified (AWG) wire range (Red, 22-18: Blue, 16-14). The connector line shall offer a tongue variations (sized to grip male tabs: 0.250 x 0.032 or 0.187 x Insulated connectors shall be UL Listed and CSA 0.020 per ANSI/NEMA CD-2) and barrel variations in Certified for 600 V building wire 1000V signs or wire (AWG) size (22-18, 167-14, 12-10) and fixtures (luminaires) and temperature rated 221F construction (non-insulated, vinyl insulated, nylon (105C) maximum. fully, etc.). The Female Disconnects shall have regulatory agency coverage (UL Listing, CSA Female Disconnects shall be suitable for field or Certification). The tongue portion shall be marked with factory wiring, with a UL Recognized strain relief the wire range and manufacturers symbol ( ). required. 3M and Scotchlok are trademarks of 3M IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Litho in USA.