W Highland Terminals C L E FV10-6 thru FV14-10 Standard Fork, Vinyl Insulated, Butted Seam Data Sheet Wire Maximum Product Range Stud Barrel Barrel Insulation Number (AWG)SWize C L E Thickness Length I.D. Diameter F0V10-6 162-1 09.3803.214.000.805.04 05.200.13 0.25 F0V10-8 182-1 09.3803.214.000.805.04 05.200.13 0.25 F0V10-10 102-1 1809.303.214.000.805.04 05.200.13 0.25 0.34 F4V14-6 166-1 00.2904.900.705.03 00.200.09 0.17 F4V14-8 186-1 09.3400.204.900.705.03 00.200.09 0.17 F4V14-10 106-1 1409.300.204.900.705.03 00.200.09 0.17 Installation Information WARNING Turn power off before installing or removing terminal. All electrical CANADIAN STANDARDS UNDERWRITERS work should be done according to appropriate electrical codes. ASSOCIATION LABORATORIES STANDARD NO. C22.2 STANDARD NO. UL 486A NO. 0. 65 3M FILE NO. E23438 UL Listed and CSA Certified for use on stranded copper 3M FILE NO. LR22190 (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Make the crimp in the proper station of a recommended 3M crimp tool: TH-440, TH-450 (scissor style), or Specifications TR-490 (ratchet style) hand tools. Wire Size: See Table Above Barrel Seam: Butted Max. Voltage Rating: 600 V Building Wire 1000 V Signs, Fixtures Barrel Crimp (Electrical) and Luminaires Max. Temperature Rating: 221F (105C) Max. Current: Same as Wire Insulator Material: Vinyl Terminal Material: ETP Copper Plating: TinEngineering Specification Crimp-type terminals shall, electrically and The vinyl-insulated, butted seam standard fork terminal mechnically, connect to a pre-stripped end of a stranded shall be tin-plated, annealed copper, with the tongue copper wire: and have a flat tongue portion with a having a specified stud slot (size 6 thru 10) and a butted central opening for mounting around a screw or stud. seam barrel covered by a molded vinyl funnel entry sleeve, color coded and sized, for a specified (AWG) The terminal line shall offer tongue variations in hole wire range (16-14, 12-10). (stud) size (6, 8 10, etc.) and configuration (ring, fork, block fork, flanged block fork, locking fork, etc.): and Insulated terminals shall be UL Listed and CSA barrel variations in wire (AWG) size (22-18, 16-14, 12- Certified for 600 Volts maximum building wire: 1000 10, etc.) and construction (non-insulated brazed seam, Volts maximum in signs, fixtures and luminaries and vinyl insulated butted seam, nylon insulated with have a maximum operating temperature of 221F insulation grip, etc.). The terminal line shall have (105C). regulatory agency coverage (UL Listing, CSA Certification). The terminal tongue shall be marked with the wire range and manufacturers symbol ( ). 3M and Highland are trademarks of 3M IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Litho in USA.