8 7 6 5 4 3 2 1 NOTES 1. TM REGULATORY INFORMATION: TABLE 1 3M ROUND CONDUCTOR FLAT LSHF CABLE, HF447 SERIES VISIT 3M.com/regs OR CONTACT YOUR 3M NUMBER OF 3M PART REPRESENTATIVE TO FIND THE RoHS COMPLIANCE DIM. DIM025 30 AWG SOLID CONDUCTORS NUMBER STATUS OF THE 3M PART YOU ARE INTERESTED IN. 10 HF447/10 .250 .006 6.35 .225 .004 5.72 12 HF447/12 .300 .006 7.62 .275 .004 6.99 UL FILE: E42769 STYLE: 22088 14 HF447/14 .350 .006 8.89 .325 .004 8.26 DIM. 16 HF447/16 .400 .006 10.16 .375 .004 9.53 2 IN THE EVENT OF CONFLICT BETWEEN THIS DATA 20 HF447/20 .500 .006 12.70 .475 .004 12.07 AND THAT CONTAINED IN THE PRODUCT 26 HF447/26 .650 .006 16.51 .625 .004 15.88 D D SPECIFICATION, THE PRODUCT SPECIFICATION 30 HF447/30 .750 .006 19.05 .725 .004 18.42 TAKES PRECEDENT. 34 HF447/34 .850 .009 21.59 .825 .006 20.96 DIM. 3. UL HAS TESTED THE INSULATION MATERIAL 36 HF447/36 .900 .009 22.86 .875 .006 22.23 UNDER UL2885 AND DETERMINED THEM TO BE 40 HF447/40 1.000 .009 25.40 .975 .006 24.77 .013 .005 HALOGEN FREE. THE UL REFERENCE FILE 50 HF447/50 1.250 .009 31.75 1.225 .006 31.12 INSULATION NUMBER IS E118773. PLEASE SEE TABLE 2 0.13 0.33 60 HF447/60 1.500 .012 38.10 1.475 .009 37.47 FOR THE EQUIVALENT IEC TEST STANDARDS. 68 HF447/68 1.700 .012 43.18 1.675 .009 42.55 4. UL HAS TESTED THE COMPLETE CABLE UNDER 80 HF447/80 2.000 .015 50.80 1.975 .011 50.17 IEC 61034-2 FOR LOW SMOKE CHARACTERISTICS. 100 HF447/100 2.500 .015 63.50 2.475 .012 62.87 THE UL REFERENCE FILE NUMBER IS E42769. THE SMOKE TEST OF IEC 61034-2025 .003 .025 .002 30 AWG .254 TINNED 0.08 0.64 0.05 0.64 SOLID COPPER CONDUCTORS TABLE 2 TYP. ASSESSMENT HALOGENS IEC62821-1, 62821-2 (CHLORINE, BROMINE & FLUORINE) AND 60684-2 DETERMINATION OF THE HALOGEN IEC 60754-1:2011, ACID GAS CONTENT BS EN60754-1:2014 DETERMINATION OF ACIDITY (BY pH MEASUREMENT) AND IEC 60754-2 CONDUCTIVITY C C UL LOW SMOKE HALOGEN FREE (LSHF) WIRE AND CABLE MARK COVERED UNDER IEC 62821-1,2,3 SERIES-UL 2885 HARMONIZED TO EU, INTERNATIONAL STANDARDS. ORDERING INFORMATION HF447/XX-XX 2 PHYSICAL: INSULATION: BLANK = STANDARD MATERIAL: LSHF EVA/PO NUMBER OF CONDUCTORS SF = SPLICE FREE COLOR: DARK GRAY (SEE TABLE 1) MARKING: STANDARD: NONE NOTE: CANADIAN: SEEPRINTING ILLUSTRATIO VIEW AVAILABLE IN STANDARD LENGTHS OF 100 ft AND 300 ft PER ROLL, PRIMARY CABLE: BLUE MARKING ON ONE EDGE OF CABLE DESIGNATES WIRE NUMBER 1. PLEASE SPECIFY WHEN ORDERING. CONTACT 3M FOR AVAILABILITY OF ADDITIONAL CONDUCTOR COUNTS AND/OR CUSTOM ROLL LENGTHS. CONDUCTORS: MATERIAL: 30 AWG ( .254 TINNED SOLID COPPER 2 ELECTRICAL: B B VOLTAGE RATING: USA 150V CANADIAN 150V EU: <50V 10 INSULATION RESISTANCE: (PRIMARY CABLE) >1 X 10 /10ft. 3m UNBALANCED BALANCED CHARACTERISTIC IMPEDANCE: 80 134 CAPACITANCE: 19.68 pF/ft 64.6 pF/m 11.2 pF/ft 36.5 pF/m INDUCTANCE: .13 H/ft .43 H/m .2 H/ft .66 H/m PROPAGATION DELAY: 1.57 ns/ft 5.15 ns/m 1.49 ns/ft 4.89 ns/m VELOCITY OF PROPAGATION: 65% 65% NOTE: UNBALANCED IS MEASURED BETWEEN GROUND-SIGNAL-GROUND CONDUCTORS. BALANCED IS MEASURED BETWEEN CONDUCTORS WITHIN A PAIR. 2 ENVIRONMENTAL: INCH MM TEMPERATURE RATING: -40 C TO 90 C TOLERANCE - UNLESS NOTED FLAMMABILITY RATING: UL: HORZONTAL XX .XX INCH .1 .01 .005 C 72311 MAR 28,2017 JNC WL = DIM. FOR REFERENCE ONLY REDRAWN TO NEW FORMAT WITH DATA CHANGES DESIGN REFERENCE NEXT ASSEMBLY REV ECO ISSUE DATE AND DESCRIPTION DRFT CHKD ACCESS DRFT DATE MFG DATE CODES CASTIGLIONE FEB 21,2017 CHKD DATE APPVL DATE R. YANG FEB 21,2017 R. EDWARDS FEB 21,2017 A A CANADIAN OPTION DIVISION DIVISION CODE C 3M COPYRIGHT 2017 3M Center EMSD This document and the information it contains are 3M property and may not be reproduced or further St. Paul,PRINTING ILLUSTRATIO SCALE TOLERANCES DO NOT distributed without 3M permission, or used or EXCEPT AS MN 55144 disclosed other than for 3M authorized purposes. SCALE All rights reserved. NOTED DRAWING TITLE R INCHES .0 3M ELECTRONICS MATERIALS SOLUTIONS DIVISION ROUND CONDUCTOR FLAT .00 AWM 22088 90C 150V LSHF 3M NU INTERCONNECT SOLUTIONS .000 LSHF CABLE, HF447 THIRD ANGLE PROJECTION .0000 8 7 6 5 4 3 2 1 TM 3M ROUND CONDUCTOR FLAT LSHF CABLE, HF447 SERIES .025 30 AWG SOLID D D Technical Information: The technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed. Product Use: Many factors beyond 3M s control and uniquely within user s knowledge and control can affect the use and performance of a 3M product in a particular application. Given C C the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for user s method of application. Warranty, Limited Remedy, and Disclaimer: Unless an additional warranty is specifically stated on the applicable 3M product packaging or product literature, 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the product. 3M MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. If the 3M product does not conform to this warranty, then the sole and exclusive remedy is, at 3M s option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. B B Unless otherwise noted, references to indrustry specifications are intended to indicate substantial compliance to the material elements of the specification. Such references should not be construed as a guarantee of compliance to all requirements in a given specification. C 72311 MAR 28,2017 JNC WL REDRAWN TO NEW FORMAT WITH DATA CHANGES DESIGN REFERENCE NEXT ASSEMBLY REV ECO ISSUE DATE AND DESCRIPTION DRFT CHKD ACCESS DRFT DATE MFG DATE CODES CASTIGLIONE FEB 21,2017 CHKD DATE APPVL DATE R. YANG FEB 21,2017 R. EDWARDS FEB 21,2017 A A DIVISION DIVISION CODE C 3M COPYRIGHT 2017 3M Center EMSD This document and the information it contains are 3M property and may not be reproduced or further St. Paul, SCALE TOLERANCES DO NOT distributed without 3M permission, or used or EXCEPT AS MN 55144 disclosed other than for 3M authorized purposes. SCALE All rights reserved. NOTED DRAWING TITLE INCHES .0 ROUND CONDUCTOR FLAT .00 .000 LSHF CABLE, HF447 THIRD ANGLE PROJECTION .0000 MILLIMETERS INTERPRET PER SERIES ASME Y14.5 - 2009 0 .0 CAGE SIZE DRAWING NO. REV. MAX SURFACE ROUGHNESS .00 NUMBER ALL SURFACES .000 78-5100-2343-1 C MODEL DET. MARKED ONLY ANGLES HF447 YES NO SHT 2 OF 2 LISTS 8 7 6 5 4 3 2 1 78-5100-2343-1 C DRAWING NUMBER REVISION Imaged: C.9 4/12/2017 1:58 PM UTC-05:00