W Highland Terminals LF10-6 thru LF18-8 C L E Locking Fork, Non-Insulated, Butted Seam Data Sheet Wire Max Product Range Stud Lock Barrel Barrel Number (AWG) SizeWWidth C L E Thickness Length I.D. L0F10-6 162-1 08.3008.203.203.700.505.04 05.2 0.13 L0F10-8 182-1 02.3508.303.203.700.505.04 05.2 0.13 L0F10-10 102-1 1602.3 08.303.203.700.505.04 05.2 0.13 L0F10-14 12-1 03.4804.404.409.900.605.04 05.2 0.13 L4F14-6 166-1 05.2705.208.200.600.505.03 00.2 0.09 L4F14-8 186-1 00.3405.308.200.600.505.03 00.2 0.09 L4F14-10 106-1 1502.3 05.308.200.600.505.03 00.2 0.09 L8F18-4 242-1 05.2705.208.200.600.505.03 00.2 0.07 L8F18-6 262-1 05.2705.208.200.600.505.03 00.2 0.07 L8F18-8 282-1 00.3405.308.200.600.505.03 00.2 0.07 Installation Information WARNING CANADIAN STANDARDS Turn power off before installing or removing terminal. All electrical UNDERWRITERS ASSOCIATION work should be done according to appropriate electrical codes. LABORATORIES STANDARD NO. C22.2 STANDARD NO. UL 486A NO. 0. 65 3M FILE NO. E23438 UL Listed and CSA Certified for use on stranded copper 3M FILE NO. LR22190 (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Specifications Make the crimp in the proper station of a recommended Wire Size: See Table Above 3M crimp tool: TH-440, TH-450 (scissor style), or Barrel Seam: Butted TR-490 (ratchet style) hand tools. Max. Current: Same as Wire Terminal Material: ETP Copper Plating: Tin Barrel Crimp (Required)Engineering Specification The non-insulated, butted seam locking fork terminal Crimp-type terminals shall, electrically and mechnical- shall be tin-plated, annealed copper, with the tongue ly, connect to a pre-stripped end of a stranded copper having a specified stud slot (size 4 thru 1/4 in.) and a wire: and have a flat tongue portion with a central opening for mounting around a screw or stud. butted seam barrel with a beveled I.D. for ease of stranded wire entry, sized for a specified (AWG) wire range (22-18, 16-14, 12-10). The terminal line shall offer tongue variations in hole (stud) size (6, 8 10, etc.) and configuration (ring, fork, Non-insulated terminals shall be UL Listed and CSA block fork, flanged block fork, locking fork, etc.): and barrel variations in wire (AWG) size (22-18, 16-14, 12- Certified. 10, etc.) and construction (non-insulated brazed seam, vinyl insulated butted seam, nylon insulated with insu- lation grip, etc.). The terminal line shall have regulato- ry agency coverage (UL Listing, CSA Certification). The terminal tongue shall be marked with the wire range and manufacturers symbol ( ). 3M and Highland are trademarks of 3M IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Litho in USA.