W Highland Terminals C L E LFV10-6 thru LFV18-8 Locking Fork, Vinyl Insulated, Butted Seam Data Sheet Wire Max Maximum Product Range Stud Lock Barrel Barrel Insulation Number (AWG) SizeWWidth C L E Thickness Length I.D. Diameter L0FV10-6 162-1 08.3008.203.213.000.805.04 05.200.13 0.25 L0FV10-8 182-1 02.3508.303.213.000.805.04 05.200.13 0.25 L0FV10-10102-1 1602.308.303.213.000.805.04 05.200.13 0.25 L0FV10-14 12-1 03.4804.404.419.200.905.04 05.200.13 0.25 L4FV14-6 166-1 05.2705.208.200.800.705.03 00.200.09 0.17 L4FV14-8 186-1 00.3405.308.200.800.705.03 00.200.09 0.17 L4FV14-10106-1 1502.305.308.200.800.705.03 00.200.09 0.17 L8FV18-4 242-1 05.2705.208.200.800.705.03 00.205.07 0.14 L8FV18-6 262-1 05.2705.208.200.800.705.03 00.205.07 0.14 L8FV18-8 282-1 00.3405.308.200.800.705.03 00.205.07 0.14 Installation Information WARNING UNDERWRITERS CANADIAN STANDARDS Turn power off before installing or removing terminal. All electrical LABORATORIES ASSOCIATION work should be done according to appropriate electrical codes. STANDARD NO. UL 486A STANDARD NO. C22.2 3M FILE NO. E23438 NO. 0. 65 3M FILE NO. LR22190 UL Listed and CSA Certified for use on stranded copper (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Specifications Make the crimp in the proper station of a recommended Wire Size: See Table Above 3M crimp tool: TH-440, TH-450 (scissor style), or Barrel Seam: Butted TR-490 (ratchet style) hand tools. Max. Voltage Rating: 600 V Building Wire 1000 V Signs, Fixtures and Luminaires Max. Temperature Rating: 221F (105C) Max. Current: Same as Wire Barrel Crimp (Electrical) Insulator Material: Vinyl Terminal Material: ETP Copper Plating: TinEngineering Specification Crimp-type terminals shall, electrically and The vinyl-insulated, butted seam locking fork terminal mechnically, connect to a pre-stripped end of a stranded shall be tin-plated, annealed copper, with the tongue copper wire: and have a flat tongue portion with a having a specified stud slot (size 4 thru 1/4 in.) and a central opening for mounting around a screw or stud. butted seam barrel covered by a molded vinyl funnel entry sleeve, color coded and sized, for a specified The terminal line shall offer tongue variations in hole (AWG) wire range (22-18, 16-14, 12-10). (stud) size (6, 8 10, etc.) and configuration (ring, fork, block fork, flanged block fork, locking fork, etc.): and Insulated terminals shall be UL Listed and CSA barrel variations in wire (AWG) size (22-18, 16-14, 12- Certified for 600 Volts maximum building wire: 1000 10, etc.) and construction (non-insulated brazed seam, Volts maximum in signs, fixtures and luminaries and vinyl insulated butted seam, nylon insulated with have a maximum operating temperature of 221F insulation grip, etc.). The terminal line shall have (105C). regulatory agency coverage (UL Listing, CSA Certification). The terminal tongue shall be marked with the wire range and manufacturers symbol ( ). 3M and Highland are trademarks of 3M IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Litho in USA.