Scotchlok Terminals W W MNU18-250DMI, MNU14-250DMI, W MNU10-250DMI D L Male Disconnect, Nylon Fully Insulated, Butted Seam Data Sheet Wire Male Tab Maximum Product Range Width (W ) Barrel Barrel Insulation Number (AWG)xLThickness WD Length I.D. Diameter M8NU18-250DMI222-105.250 x 0.03 04.900.405.305.205.06 0.14 M4NU14-250DMI126-105.250 x 0.03 04.900.405.305.200.08 0.17 M0NU10-250DMI122-105.250 x 0.03 17.009.405.300.200.15 0.25 Installation Information WARNING CANADIAN STANDARDS Turn power off before installing or removing terminal. All electrical UNDERWRITERS ASSOCIATION work should be done according to appropriate electrical codes. LABORATORIES STANDARD NO. C22.2 STANDARD NO. UL 310 NO. 153 3M FILE NO. E70512 3M FILE NO. LR22190 UL Listed and CSA Certified for use on stranded copper (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Make the crimp in the proper station of a recommended 3M crimp tool: TH-440, TH-450 (scissor style), or TR-490 (ratchet style) hand tools. Specifications Wire Size: See Table Above Barrel Crimp (Required) Barrel Seam: Butted Max. Voltage Rating: 600 V Building Wire 1000 V Signs or Fixtures (Luminaires) Max. Temperature Rating: 221F (105C) Max. Current: Same as Wire Suitable for factory application on steel or brass tabs UL Insulator Material: Nylon or CSA. Terminal Material: ETP Copper Suitable for field application on brass tabs, strain relief Plating: Tin required, UL only.Engineering Specification Crimp-Type Male Quick-Slide Connectors shall, The Nylon Insulated 0.250 Male Disconnect shall be electrically and mechanically connect permanently to tin plated 0.032 thick copper, with a 0.250 blade the prestripped end of a stranded copper wire and, conforming to ANSI/NEMA DC-2 dimension and a have a flat rectangular tongue portion for mating to a 0.25 long barrel covered by a molded nylon sleeve, Female Disconnect in a separable, reusable manner, color coded, and sized for a specified (AWG) wire forming a Quick Connect Wiring Connection. range (22-18, 16-14, 12-10). The connector line shall offer tongue variations (size Insulated connectors shall be UL Listed and CSA 0.250 x 0.032 or 0.187 x 0.020 per ANSI/NEMA Certified for 600 volts maximum, building wire: 1000 DC-2) and barrel variations in wire size 22-18 AWG, volts maximum, signs and fixtures (luminaires). The 16-14 AWG, 12-10 AWG and construction of non- connector shall be temperature rated 221F (105C) insulated, vinyl insulated nylon fully insulated, etc. maximum. The Quick-Slide Connectors shall have regulatory Quick Slide Connectors shall be suitable for field or agency coverage (UL Listing, CSA Certification). The factory wiring, with a UL Recognized strain relief tongue shall be marked with the wire range and the required. manufacturers symbol. ( ) 3M and Scotchlok are trademarks of 3M. is a trademark of Underwriters Laboratories. is a trademark of Canadian Standards Association. IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Litho in USA.