W Scotchlok Terminals MU18-4FL thru MU10-14FL C L E Locking Fork, Non-Insulated, Butted Seam Data Sheet Wire Max Product Range Stud Lock Barrel Barrel Number (AWG) SizeWWidth C L E Thickness Length I.D. M8U18-4FL242-1 05.2705.208.200.600.505.03 00.2 0.07 M8U18-6FL262-1 05.2705.208.200.600.505.03 00.2 0.07 M8U18-8FL282-1 00.3405.308.200.600.505.03 00.2 0.07 0.35 M8U18-10FL202-1 1 05.3208.200.600.505.03 00.2 0.07 M4U14-4FL146-1 05.2705.208.200.600.505.03 00.2 0.09 M4U14-6FL166-1 05.2705.208.200.600.505.03 00.2 0.09 M4U14-8FL186-1 00.3405.308.200.600.505.03 00.2 0.09 M4U14-10FL106-1 1502.305.308.200.600.505.03 00.2 0.09 M4U14-14FL146-1 18/ 03.400.400.405.900.605.03 00.2 0.09 M0U10-6FL162-1 08.3008.203.203.700.505.04 05.2 0.13 M0U10-8FL182-1 02.3508.303.203.700.505.04 05.2 0.13 M0U10-10FL102-1 1602.308.303.203.700.505.04 05.2 0.13 M0U10-14FL142-1 18/ 03.404.404.409.900.605.04 05.2 0.13 Installation Information WARNING Turn power off before installing or removing terminal. All electrical CANADIAN STANDARDS LISTED 314R work should be done according to appropriate electrical codes. ASSOCIATION UNDERWRITERS STANDARD NO. C22.2 LABORATORIES NO. 0. 65 UL Listed and CSA Certified for use on stranded copper STANDARD NO. UL 486A 3M FILE NO. LR22190 3M FILE NO. E23438 (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Make the crimp in the proper station of a recommended 3M crimp tool: TH-440, TH-450 (scissor style), or TR-490 Specifications (ratchet style) hand tools. Wire Size: See Table Above Barrel Seam: Butted Barrel Crimp (Required) Max. Current: Same as Wire Terminal Material: ETP Copper Plating: TinEngineering Specification Crimp-type terminals shall, electrically and mechanically, The non-insulated, butted seam locking fork terminal shall connect to a pre-stripped end of a stranded copper wire: be tin-plated, annealed copper, with the tongue having a and have a flat tongue portion with a central opening for specified stud slot (size 4 thru 1/4 in.) and a butted seam barrel with a beveled I.D. for ease of stranded wire entry, mounting around a screw or stud. sized for a specified (AWG) wire range (22-18, 16-14, The terminal line shall offer tongue variations in hole 12-10). (stud) size (6, 8 10, etc.) and configuration (ring, fork, block fork, flanged block fork, locking fork, etc.): and Non-insulated terminals shall be UL Listed and CSA Certified. barrel variations in wire (AWG) size (22-18, 16-14, 12-10, etc.) and construction (non-insulated brazed seam, vinyl insulated butted seam, nylon insulated with insulation grip, etc.). The terminal line shall have regulatory agency coverage (UL Listing, CSA Certification). The terminal tongue shall be marked with the wire range and manufacturers symbol ( ). 3M and Scotchlok are trademarks of 3M IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Litho in USA.