Scotchlok Terminals
C
MVU18-6FFB thru MVU10-10FFB
L
E
Flanged Block Fork, Vinyl Insulated, Butted Seam
Data Sheet
Wire Maximum
Product Range Stud Barrel Barrel Insulation
Number (AWG)SWize C L E Thickness Length I.D. Diameter
M8VU18-6FFB262-1 05.3005.200.800.705.03 00.205.07 0.14
M8VU18-8FFB282-1 05.3005.200.800.705.03 00.205.07 0.14
M8VU18-10FFB202-1 1005.305.200.800.705.03 00.205.07 0.14
0.30
M4VU14-6FFB166-1 05.2500.800.705.03 00.200.09 0.17
M4VU14-8FFB186-1 05.3005.200.800.705.03 00.200.09 0.17
M4VU14-10FFB106-1 1005.305.200.800.705.03 00.200.09 0.17
M0VU10-6FFB162-1 09.3203.214.000.805.04 05.200.13 0.25
M0VU10-8FFB182-1 09.3203.214.000.805.04 05.200.13 0.25
M0VU10-10FFB102-1 1209.303.214.000.805.04 05.200.13 0.25
Installation Information
WARNING
Turn power off before installing or removing terminal. All electrical
CANADIAN STANDARDS
LISTED 314R
work should be done according to appropriate electrical codes.
ASSOCIATION
UNDERWRITERS
STANDARD NO. C22.2
LABORATORIES
NO. 0. 65
STANDARD NO. UL 486A UL Listed and CSA Certified for use on stranded copper
3M FILE NO. LR22190
3M FILE NO. E23438
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Specifications Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or TR-490
Wire Size: See Table Above
(ratchet style) hand tools.
Barrel Seam: Butted
Max. Voltage Rating: 600 V Building Wire
1000 V Signs, Fixtures
and Luminaires
Barrel Crimp (Electrical)
Max. Temperature Rating: 221F (105C)
Max. Current: Same as Wire
Insulator Material: Vinyl
Terminal Material: ETP Copper
Plating: TinEngineering Specification
The vinyl-insulated, butted seam flanged block fork
Crimp-type terminals shall, electrically and
terminal shall be tin-plated, annealed copper, with the
mechanically, connect to a pre-stripped end of a
tongue having a specified stud slot (size 6 thru 10) and
stranded copper wire: and have a flat tongue portion
a butted seam barrel covered by a molded vinyl funnel
with a central opening for mounting around a screw or
entry sleeve, color coded and sized, for a specified
stud.
(AWG) wire range (22-18, 16-14, 12-10).
The terminal line shall offer tongue variations in hole
Insulated terminals shall be UL Listed and CSA
(stud) size (6, 8 10, etc.) and configuration (ring, fork,
Certified for 600 Volts maximum building wire: 1000
block fork, flanged block fork, locking fork, etc.): and
Volts maximum in signs, fixtures and luminaries and
barrel variations in wire (AWG) size (22-18, 16-14,
have a maximum operating temperature of 221F
12-10, etc.) and construction (non-insulated brazed
(105C).
seam, vinyl insulated butted seam, nylon insulated with
insulation grip, etc.). The terminal line shall have
regulatory agency coverage (UL Listing, CSA
Certification). The terminal tongue shall be marked
with the wire range and manufacturers symbol ().
3M and Scotchlok are trademarks of 3M
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase.
3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be,
at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will
not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential
regardless of the legal theory asserted.
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
Litho in USA.