USER GUIDE TB-9028 497AJK HEPA Vacuum Made in the Installation, Operation and Maintenance United States of America Specifications Electrical 120VAC, 50/60Hz, 6.0amps Motor 1 Horsepower Dimensions 17.8 L x 7.8 W x 9.3 H (45.2 cm L x 19.7 cm W x 23.5 cm H) Weight 11 lbs. Certification cULus To Operate 1. Release latches and open lid. 2. Unfasten accessory door and remove vacuum hose, electrical cord and hose attachments. 3. Remove filter plug from vacuum inlet (always Figure 1. 497AJK HEPA Vacuum. replace when repacking for transport). 4. Attach selected accessory to hose. Insert other end Grounding Instructions of hose into inlet. This appliance must be grounded. If it should 5. Latch lid securely. malfunction or break down, grounding provides a 6. Insert hooded end of power cord in power cord path of least resistance for electric current to reduce receptacle on vacuum. the risk of electric shock. This appliance is equipped 7. Plug cord into power outlet. with a cord having an equipment-grounding conductor 8. Turn on power switch. and grounding plug. The plug must be used with an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. This appliance is for use on a nominal 120-volt circuit. (Check inside each vacuum model motor lid for specific information.) Make sure the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance. Any service on this vacuum cleaner should be performed by an authorized service representative. Warning: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance. If the plug does not fit the outlet, have a Figure 2. How to operate the 497AJK HEPA Vacuum. proper outlet installed by a qualified electrician. SCS - 926 JR Industrial Drive, Sanford, NC 27332 (919) 718-0000 Website: StaticControl.com 2016 DESCO INDUSTRIES, INC. TB-9028 Page 1 of 3 May 2016 Employee OwnedTo Replace Filter The SCS 497AJK HEPA Vacuum is designed for use with disposable SCS Filters. The filters must be replaced on a regular basis. Frequency of filter replacement depends on the type and frequency of use of the 497AJK HEPA Vacuum. 1. Release the latches and open the lid. 2. Remove red filter plug or hose. Save the plug for use later (see WEEE Statement). 3. Grasp the filter on each side by using the circular indentations. Pull filter straight up by both ends. Figure 3. 497AJK HEPA Vacuum parts. 4. Insert the red filter plug in the filter. 5. Dispose of the filter in a suitable manner. Safety Information 6. Remove the red plug from the new filter and position Warning: TO REDUCE THE RISK OF FIRE, ELECTRIC filter in the vacuum with the filter hole to your left. SHOCK OR INJURY, FOLLOW THESE SAFETY Save the red plug for use in disposing of the filter RULES: (see WEEE Statement). 7. Verify that the gasket between the filter and the 1. Use only as described in this manual. Use only motor fits tightly. manufacturers recommended attachments. 8. Insert the red filter plug or hose. 2. Do not use this machine to vacuum hazardous dust, 9. Close and latch the lid. flammable or combustible liquids, such as gasoline. 3. Do not use without filter in place. To Store Attachments for Transport 4. Do not leave appliance plugged in when not in use. Unplug from outlet when not in use and before 1. Unplug the power cord from the outlet and vacuum. servicing. 2. Open the lid and retrieve the filter plug. 5. Do not handle plug or appliance with wet hands. 3. Remove the hose from the inlet and insert the filter 6. Do not use appliance outdoors or on wet surfaces. plug. Electric shock could occur. 4. Detach the hose nozzle from the base. 7. Do not use with damaged cord or plug. If appliance 5. Place the hose, power cord and attachments into the is not working as it should, has been dropped lid and close the accessory door. or damaged, left outdoors, or dropped in water, 6. Close the lid and securely fasten the latches. discontinue use. 8. Keep cord away from heated surfaces. Parts List 9. Do not put any object into openings. Do not use with Item Description any opening blocked. 1. SV-PC8 8 Foot Power Cord 10. Connect to a properly grounded outlet only. See 2. HEPA VACUUM HOSE-32 5 Foot Hose Grounding Instructions. 11. Use extra care when cleaning on stairs. 3. SV-CN1 Crevice Nozzle 12. Turn off all controls before unplugging. 4. SV-SPF1 Type 1 Fine Particle Filter 13. Do not pull or carry by cord, use cord as a handle, 5. SV-CB1 Crevice Brush close door on cord or pull cord around sharp edges 6. SV-CS1 Carrying Strap and corners. Keep cord away from heated surfaces. 14. Do not allow to be used as a toy. Close attention is necessary when used near children. 15. Keep hair, loose clothing, fingers and all body parts away from openings and moving parts. 16. Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes. 17. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. Notice: Do not operate when filter is full. A lack of suction or exhaust is an indication of a full filter. 18. The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge. 19. Do not allow children to use as a toy. Close attention is necessary when used near children. SCS - 926 JR Industrial Drive, Sanford, NC 27332 (919) 718-0000 Website: StaticControl.com 2016 DESCO INDUSTRIES, INC. TB-9028 Page 2 of 3 Employee Owned