Data Sheet
GE
PIM400 Series; ATCA Board Power Input Modules
-36 to -75 Vdc; 400W/10A
Features
-48V/10A Dual redundant input power distribution
3.3Vdc/3.6A & 5.0Vdc/150mA of isolated Management Power
for IPM or other housekeeping functions
Independent holdup capacitor charging voltage; trimmable
from 50 to 95Vdc for optimal real estate
ORing functionality, Inrush protection & hot swap capability
Integral EMI filter designed for the ATCA board to meet CISPR
Class B with minimal external filtering
Protection: Reverse polarity, under voltage, input transient
over voltage/current and temperature
2
I C digital interface options
Applications
Isolated A/B Feed Loss /Open Fuse Alarm
ATCA Front Board / Blade
High efficiency : 98%
Central Office Telecom equipment
-40 to 85C ambient temperature operation
High availability server and storage applications
Industry Standard Quarter brick size: 58.4 mm x 36.8 mm x
13.7 mm (2.3 in x 1.45 in x 0.54 in)
MTBF : 2,308,563 hours per TELCORDIA
Compliant to RoHS Directive 2011/65/EU and amended
Options
Directive (EU) 2015/86 and Compliant to REACH Directive (EC)
No 1907/2006
Choice of short pin lengths
#
2 ANSI/UL 62368-1 and CAN/CSA C22.2 No. 62368-1
I C Digital Interface
Recognized, DIN VDE 0868-1/A11:2017 (EN62368-
1:2014/A11:2017)
Meets the voltage and current requirements for ETSI 300-132-
2 and complies with and licensed for Basic insulation rating per
EN60950-1
2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE
standards
ISO**9001 and ISO 14001 certified manufacturing facilities
Description
The PIM400 series of Power Input Modules are designed to greatly simplify the task of implementing dual redundant, hot swap 48Vdc
2
power distribution with EMI filtering on an ATCA or other telecom boards. The PIM400 with optional I C digital interface capability,
TM TM
when used with a variety of GEs series of Bus converters (Barracuda Series) /POLs (DLynx Series) provides for a quick, simple and
elegant power solution to a wide variety of demanding & intelligent power system architectures.
* UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
September 1, 2020 2015 General Electric Company. All rights reserved.
Data Sheet
GE
PIM400 Series; ATCA Board Power Input Modules
-36 to -75 Vdc; 400W/10A
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only,
functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of
the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter Device Symbol Min Typ Max Unit
Input Voltage
Continuous All V -0.5 -75 V
I dc
Transient (Pulse duration = 1ms, square wave) All V -100 V
tr dc
Additionally: Transient Input Undervoltage, Overvoltage
All
and Impulse per ANSI T1.315-2001(R2006)
Reverse Polarity Protection +75V Vdc
Holdup Capacitor
Voltage (with respect to -48V_OUT) All V HLDP 100 V
_ dc
Capacitance All C_HLDP 100 3300 F
Temperature
Normal Operating Ambient Temperature
o
All T -40 85 C
A
(See Thermal Considerations section)
o
Storage Temperature All Tstg -55 125 C
Isolation Voltage
Input to MGMT_PWR Output Voltage & Alarm All 2250 Vdc
Input to SHELF_GND Voltage All 2250 Vdc
Input to LOGIC_GND Voltage All 2250 Vdc
CAUTION:
1. This power module is not internally fused. Both A & B feeds and their corresponding returns must be individually
fused.
To preserve maximum flexibility, internal fusing is not included. However, to achieve maximum safety and system protection, the safety
agencies require a fast-acting fuse with a maximum rating of 20 Amps and Voltage Rating >/= 75Vdc for the 48AF, -48BF VRTN_AF &
VRTN_BF feeds. Consult Fusing and fault protection Section of PICMG 3.0 ATCA specifications for additional information. Based on the
information provided in this data sheet on inrush current and maximum dc input current, the same type of fuse with a lower rating can
be used. Refer to the fuse manufacturers data sheet for further information.
September 1, 2020 2015 General Electric Company. All rights reserved. Page 2