Data sheet Manual motor starter MS132 Manual motor starters are electro- mechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short- circuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors. Description Order data Overload protection trip class 10 MS132 screw terminal Phase loss sensitivity Disconnect function Setting Type Trip Order code Pack- Weight Temperature compensation from -25 +60 C range class ing unit per PCE Adjustable current setting for overload protection A PCE kg Suitable for three- and single-phase application 0.10...0.16 MS132-0.16 10 1SAM350000R1001 1 0.215 Trip-free mechanism 0.16...0.25 MS132-0.25 10 1SAM350000R1002 1 0.215 Status indication for short-circuit trip 0.25...0.40 MS132-0.4 10 1SAM350000R1003 1 0.215 0.40...0.63 MS132-0.63 10 1SAM350000R1004 1 0.215 Clear switch position indication ON/OFF/TRIP 0.63...1.00 MS132-1.0 10 1SAM350000R1005 1 0.215 Lockable handle 1.00...1.60 MS132-1.6 10 1SAM350000R1006 1 0.265 1.60...2.50 MS132-2.5 10 1SAM350000R1007 1 0.265 2.50...4.00 MS132-4.0 10 1SAM350000R1008 1 0.265 4.00...6.30 MS132-6.3 10 1SAM350000R1009 1 0.265 6.30...10.0 MS132-10 10 1SAM350000R1010 1 0.265 8.00...12.0 MS132-12 10 1SAM350000R1012 1 0.310 10.0...16.0 MS132-16 10 1SAM350000R1011 1 0.310 16.0...20.0 MS132-20 10 1SAM350000R1013 1 0.310 20.0...25.0 MS132-25 10 1SAM350000R1014 1 0.310 25.0...32.0 MS132-32 10 1SAM350000R1015 1 0.310 Note: MS132 with pre-assembled auxiliary contact HKF1-11, please order as follow 1SAM350005Rxxxx 2CDC241003V0013Functional description 1 Terminals 1L1, 3L2, 5L3 2 Switch position TRIP 1 3 Lockable handle 4 Test function 2 5 Status indication for short-circuit 3 4 6 Current setting range / Adjustable current setting for overload protection 5 7 Terminals 2T1, 4T2, 6T3 6 7 Application The manual motor starters protect the load and the installation against short-circuit and overload. They are three pole protection devices with thermal tripping elements for overload protection and electromagnetic tripping elements for short- circuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads. The manual motor starters have a setting scale in amperes, which allows the direct adjusting of the device without any additional calculation. In compliance with international and national standards, the setting current is the rated current of the motor and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I I = setting current). Operation mode Single-phase operation Three-phase operation Single-phase operation Wiring diagram 1L1 3L2 5L3 2T1 4T2 6T3 2 - 2CDC131021D0202 2CDC242033F0013 2CDC242023F0009 2CDC242025F0009 2CDC242028F0013 2CDC242024F0009