Product leaflet Three phase electricity meters C13 EQ meters in Steel version from ABB The compact and versatile EQ meter C13 is a three phase meter with outstanding performance. It can be used in most of the common applications for reliable and trustworthy metering of energy usage. EQ meters C13 is mainly intended for stand-alone applications. General features levels arlevels arlevels arlevels are easily configure easily configure easily configure easily configured on the meter with the push button.ed on the meter with the push button.ed on the meter with the push button.ed on the meter with the push button. C13 is a three phase direct connected meter up to 40 A. When used as alarm the output can contrWhen used as alarm the output can control an exterol an external ap-nal ap- The C13 is measuring active energy with accuracy class B paratus like a contactor (connected via an external relay) or an paratus like a contactor (connected via an external relay) or an (Cl. 1). The low rated or base currents of this product ensures alarm indicator. high dynamic performance with superior accuracy even at low currents. Navigation of the meter is easily done via the push- Approvals button below the display. The low power consumption of the The C13 meters are type approved according to IEC as well as meter, less than 1.5 VA, makes it economical in the long run - type approved and optionally verified according to MID. an important feature specially for large meter populations. MID is the Measure Instruments Directive 2004/22/EC from European Commission. The type approval is according to stan- Instrumentation dards that covers all relevant technical aspects of the meter. The C13 meter supports reading of instrument values. A large These include climate conditions, electromagnetic compatibility number of electrical properties can be read. (EMC), electrical requirements, mechanical requirements and accuracy. Active power - Total and per phase Voltage - Total and per phase Current - Total and per phase Ordering details Power factor 40 A direct connected, 3 DIN Voltage V Accuracy Type Order code Weight Output Class 1 pc The C13 meter has one solid state relay output that can be Steel Active energy, pulse output used for S0 pulses or as alarm output. C13 can generate ) 3 x 230/400 V AC Class B(Cl. 1) C13 110 - 100 * 2CMA100191R1000 0.17 pulses proportionally to the measured energy and the pulses Class 1 C13 110 - 300 2CMA100192R1000 0.17 can be used for various applications such as automatic meter ) reading systems etc. When used as alarm the quantity and * MID approvalC13 Technical data Wiring diagram C13 C13 Voltage/current inputs Nominal voltage 3x230/400 V AC 1 4 6 7 9 12 3 10 Voltage range 3x220 - 240 V AC (-20% - +15%) Power dissipation voltage circuits 1.5 VA (0.6 W) total L1 Power dissipation current circuits 0.04 VA (0.04 W) per phase at 230 V AC and I b L2 Base current I 5 A b L3 N Reference current I 5 A ref Transitional current I 0.5 A tr Maximum current I 40 A max Minimum current I 0.25 A min Starting current I < 20 mA st 2 Terminal wire area 0.5 - 10 mm Dimensions Recommended tightening torque 0.8 Nm Pulse indicator (LED) Pulse frequency 1000 imp/kWh Pulse length 40 ms General data Frequency 50 or 60 Hz 5% Accuracy Class B (Cl. 1) Active energy 1% Display of energy 6 digit LCD Environmental Operating temperature -25C - +70C Storage temperature -25C - +85C Humidity 75% yearly average, 95% on 30 days/year Resistance to fire and heat Terminal 960 C, cover 650C (IEC 60695-2-1) 54 54 Resistance to water and dust IP20 on terminal block without protective enclosure and IP51 in protective 58 58 65 65 enclosure, according to IEC 60529. Mechanical environment Class M1 in accordance with the Measuring Instrument Directive (MID). (2004/22/EC). Electromagnetic environment Class E2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC). Outputs ABB AB Current 2 - 100 mA Meters Voltage 5 - 40 V DC. Pulse output frequency 100 (imp/kWh) Box 1005 Pulse length 200 ms SE-611 29 NYKPING, Sweden 2 Terminal wire area 0.5 - 6 mm Telephone +46 155 29 50 00 Recommended tightening torque 0.8 Nm EMC compatibility Impulse voltage test 6 kV 1.2/50s (IEC 60060-1) www.abb.com Surge voltage test 4 kV 1.2/50s (IEC 61000-4-5) Fast transient burst test 4kV (IEC 61000-4-4) Immunity to electromagnetic HF-fields 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3) Copyright 2014 ABB. All rights reserved. Specification subject to Immunity to conducted disturbance 150 kHz - 80 MHz (IEC 61000-4-6) change without notice. Immunity to disturbance with harmonics 2 kHz - 150 kHz This QR-code is linked to our web site Radio frequency emission EN 55022, class B (CISPR22) www.abb.com/lowvoltage. Electrostatic discharge 15 kV (IEC 61000-4-2) You will have to download a QR-code reader Standards IEC 62052-11, IEC 62053-21 class 1, GB/T 17215.211-2006, GB/T app to your phone in order to use it. 17215.321-2008 class 1, GB 4208-2008, EN 50470-1, EN 50470-3 category B Mechanical Material Glass reinforced polycarbonate Dimensions Width 54 mm Height 122 mm Depth 65 mm DIN modules 3 122 122 94 9489 89 Product leaflet 2CMC486007L0201, rev. A, June 2014 Prod ABB AB, LP/XM