AF16Z-30-10-20 General Information Extended Product Type: AF16Z-30-10-20 Product ID: 1SBL176001R2010 EAN: 3471523113800 Catalog Description: AF16Z-30-10-20 12-20VDC Contactor Long Description: AF16Z contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF..Z contactors include an electronic coil interface accepting a wide control voltage Uc min.. Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. AF..Z contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF..Z contactors allow direct control by PLC-output 24 V DC 500 mA and obtain a reduced holding coil consumption. AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz AF..Z contactors have built-in surge protection and do not require additional surge suppressors The AF... series 1-stack 3- pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks. (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated for AF..Z-30-..-20 contactors. Only AF..Z-30-..-20 contactors need to respect the polarity on the coil terminals (A1+ and A2-). - Accessories: a wide range of accessories is available. Categories Products Low Voltage Products and Systems Control Products Contactors Block Contactors Ordering Minimum Order Quantity: 1 piece Customs Tariff Number: 85369085 EAN: 3471523113800 Dimensions Product Net Depth: 77 mm Product Net Height: 86 mm Product Net Weight: 0.310 kg Product Net Width: 45 mm Container Information Package Level 1 Width: 87 mm Package Level 1 Length: 79 mm Package Level 1 Height: 47 mm Package Level 1 Gross Weight: 0.31 kg Package Level 1 EAN: 3471523113800 Package Level 2 Units: 54 piece Package Level 2 Width: 250 mm Package Level 2 Length: 300 mm Package Level 2 Height: 315 mm Package Level 3 Units: 1296 piece Package Level 1 Units: 1 piece Technical Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 1 Number of Auxiliary Contacts NC: 0 Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14 Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 C 35 A Current (I ): acc. to IEC 60947-5-1, q = 40 C 16 A th Rated Operational Current AC-1 (I ): (690 V) 40 C 30 A e (690 V) 60 C 30 A (690 V) 70 C 26 A Rated Operational Current AC-3 (I ): (220 / 230 / 240 V) 60 C 18 A e (380 / 400 V) 60 C 18 A (415 V) 60 C 18 A(440 V) 60 C 18 A (500 V) 60 C 15 A (690 V) 60 C 10.5 A Rated Operational Power AC-3 (P ): (220 / 230 / 240 V) 4 kW e (380 / 400 V) 7.5 kW (400 V) 7.5 kW (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW Rated Operational Current AC-15 (220 / 240 V) 4 A (I ): (24 / 127 V) 6 A e (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A Rated Short-time Withstand Current at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 150 A (I ): at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 35 A cw at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A Maximum Electrical Switching AC-1 600 cycles per hour Frequency: AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour Rated Operational Current DC-13 (110 V) 0.55 A / 60 W (I ): (125 V) 0.55 A / 69 W e (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W Rated Insulation Voltage (U): acc. to UL/CSA 600 V i acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage 6 kV (U ): imp Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (U ): DC Operation 12 ... 20 V c Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75...4 mm Flexible with Insulated Ferrule 2x 0.75...2.5 mm Flexible with Ferrule 1/2x 0.75...6 mm Rigid 1/2x 1...6 mm Connecting Capacity Auxiliary Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Circuit: Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1...2.5 mm Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type: Screw Terminals Number of Main Contacts NO: 3 Environmental Climatic Withstand: Category B according to IEC 60947-1 Annex Q Maximum Operating Altitude 3000 m Permissible: