AF265-30-11-14 250-500V 50/60Hz / DC General Information Extended Product Type: AF265-30-11-14 250-500V 50/60Hz / DC Product ID: 1SFL547002R1411 EAN: 7320500481219 Catalog Description: AF265-30-11-14 Contactor Long Description: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By- pass and Distribution application up to max 1000 V. Operated with wide control voltage range 250-500 V, 50/60 Hz and DC Categories Products Low Voltage Products and Systems Control Products Contactors Block Contactors Ordering Minimum Order Quantity: 1 piece Customs Tariff Number: 85364900 EAN: 7320500481219 Dimensions Product Net Depth: 180.0 mm Product Net Height: 225.0 mm Product Net Weight: 4.640 kg Product Net Width: 140.0 mm Container Information Package Level 1 Width: 223 mm Package Level 1 Length: 175 mm Package Level 1 Height: 270 mm Package Level 1 Gross Weight: 5.31 kg Package Level 1 EAN: 7320500481219 Package Level 1 Units: 1 piece Technical Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 1 Number of Auxiliary Contacts NC: 1 Rated Operational Voltage: Main Circuit 1000 V Rated Frequency (f): Main Circuit 50/60 Hz Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 C 400 A Current (I ): th Rated Operational Current AC-1 (I ): (690 V) 55 C 350 A e (690 V) 40 C 400 A (1000 V) 40 C 350 A (1000 V) 55 C 300 A (690 V) 70 C 290 A (1000 V) 70 C 240 A Rated Operational Current AC-3 (I ): (1000 V) 55 C 100 A e (690 V) 55 C 250 A (415 V) 55 C 265 A (220 / 230 / 240 V) 55 C 265 A (440 V) 55 C 265 A (380 / 400 V) 55 C 265 A (500 V) 55 C 250 A Rated Operational Power AC-3 (P ): (500 V) 200 kW e (1000 V) 132 kW (690 V) 200 kW (220 / 230 / 240 V) 75 kW (380 / 400 V) 132 kW (440 V) 160 kW (415 V) 132 kW Rated Breaking Capacity AC-3 acc. 8 x Ie AC-3 to IEC 60947-4-1: Rated Making Capacity AC-3 acc. to 10 x Ie AC-3 IEC 60947-4-1: Short-Circuit Protective Devices: gG Type Fuses 500 A Rated Short-time Withstand Current at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 400 A (I ): at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A cwat 40 C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 865 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A Maximum Electrical Switching AC-3 300 cycles per hour Frequency: AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour Rated Operational Current DC-1 (I ): (110 V) 2 Poles in Series, 40 C 350 A e (220 V) 3 Poles in Series, 40 C 350 A Rated Operational Current DC-3 (I ): (110 V) 2 Poles in Series, 40 C 350 A e (220 V) 3 Poles in Series, 40 C 350 A Rated Operational Current DC-5 (I ): (110 V) 2 Poles in Series, 40 C 350 A e (220 V) 3 Poles in Series, 40 C 350 A Rated Insulation Voltage (U): acc. to UL/CSA 600 V i acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V Rated Impulse Withstand Voltage Main Circuit 8 kV (U ): imp Mechanical Durability: 5 million Maximum Mechanical Switching 300 cycles per hour Frequency: Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min.. 1.1 x Uc Max. (at 70 C) C Rated Control Circuit Voltage (U ): 60 Hz 250500 V c 50 Hz 250500 V DC Operation 250500 V Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 420 VA Holding at Max. Rated Control Circuit Voltage DC 4.7 W Holding at Max. Rated Control Circuit Voltage 50 Hz 20.4 VA Pull-in at Max. Rated Control Circuit Voltage DC 600 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 420 VA Holding at Max. Rated Control Circuit Voltage 60 Hz 20.4 VA Operate Time: Between Coil Energization and NO Contact Closing 2555 ms Between Coil De-energization and NO Contact Opening 3747 ms Connecting Capacity Main Circuit: Rigid Al-Cable 1x185240 mm Rigid Cu-Cable 1x6300 mm Flexible 2x70185 mm Connecting Capacity Auxiliary Solid 2x14 mm Circuit: Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 1x14 mm Flexible 2x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 Terminal Type: Main Circuit: Bars Number of Main Contacts NO: 3 Environmental Maximum Operating Altitude 3000 m Permissible: RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C Technical UL/CSA General Use Rating UL/CSA: (600 V AC) 350 A Horsepower Rating UL/CSA: (208 V AC) Three Phase 75 Hp (440 ... 480 V AC) Three Phase 200 Hp (550 ... 600 V AC) Three Phase 250 Hp (220 ... 240 V AC) Three Phase 100 Hp (200 V AC) Three Phase 75 Hp Maximum Operating Voltage Main Circuit 600 V UL/CSA: Certificates and Declarations (Document Number) Instructions and Manuals: 1SFC100008M0201 CB Certificate: SE-73042M1 Data Sheet, Technical Information: 1SFC101070D0201 Declaration of Conformity - CE: 2CMT004749 RINA Certificate: ELE060313XG/002 RoHS Information: 1SFC101055D0202