AF30Z-30-00-20 General Information Extended Product Type: AF30Z-30-00-20 Product ID: 1SBL276001R2000 EAN: 3471523114401 Catalog Description: AF30Z-30-00-20 12-20VDC Contactor Long Description: AF30Z contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF..Z contactors include an electronic coil interface accepting a wide control voltage Uc min.. Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. AF..Z contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF..Z contactors allow direct control by PLC-output 24 V DC 500 mA and obtain a reduced holding coil consumption. AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz AF..Z contactors have built-in surge protection and do not require additional surge suppressors The AF... series 1-stack 3- pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks. (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated for AF..Z-30-..-20 contactors. Only AF..Z-30-..-20 contactors need to respect the polarity on the coil terminals (A1+ and A2-). - Accessories: a wide range of accessories is available. Categories Products Low Voltage Products and Systems Control Products Contactors Block Contactors Ordering Minimum Order Quantity: 1 piece Customs Tariff Number: 85369085 EAN: 3471523114401 Dimensions Product Net Depth: 86 mm Product Net Height: 86 mm Product Net Weight: 0.350 kg Product Net Width: 45 mm Container Information Package Level 1 Width: 87 mm Package Level 1 Length: 87 mm Package Level 1 Height: 47 mm Package Level 1 Gross Weight: 0.35 kg Package Level 1 EAN: 3471523114401 Package Level 2 Units: 45 piece Package Level 2 Width: 250 mm Package Level 2 Length: 300 mm Package Level 2 Height: 315 mm Package Level 3 Units: 1080 piece Package Level 1 Units: 1 piece Technical Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 0 Number of Auxiliary Contacts NC: 0 Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14 Rated Operational Voltage: Main Circuit 690 V Rated Frequency (f): Main Circuit 50 / 60 Hz Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 C 50 A Current (I ): th Rated Operational Current AC-1 (I ): (690 V) 40 C 50 A e (690 V) 60 C 42 A (690 V) 70 C 37 A Rated Operational Current AC-3 (I ): (220 / 230 / 240 V) 60 C 33 A e (380 / 400 V) 60 C 32 A (415 V) 60 C 32 A (440 V) 60 C 32 A (500 V) 60 C 28 A(690 V) 60 C 21 A Rated Operational Power AC-3 (P ): (220 / 230 / 240 V) 9 kW e (380 / 400 V) 15 kW (400 V) 15 kW (415 V) 15 kW (440 V) 18.5 kW (500 V) 18.5 kW (690 V) 18.5 kW Rated Short-time Withstand Current at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 350 A (I ): at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 50 A cw at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 700 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 225 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A Maximum Electrical Switching AC-1 600 cycles per hour Frequency: AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour Rated Insulation Voltage (U): acc. to UL/CSA 600 V i acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage 6 kV (U ): imp Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (U ): DC Operation 12 ... 20 V c Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 1.5...10 mm Flexible with Insulated Ferrule 2x 1.5...4 mm Flexible with Ferrule 1/2x 1.5...10 mm Rigid 1/2x 2.5...10 mm Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm Wire Stripping Length: Control Circuit 10 mm Main Circuit 14 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type: Screw Terminals Number of Main Contacts NO: 3 Environmental Climatic Withstand: Category B according to IEC 60947-1 Annex Q Maximum Operating Altitude 3000 m Permissible: Resistance to Vibrations acc. to IEC 5 ... 300 Hz 4 g closed position / 2 g open position 60068-2-6: Resistance to Shock acc. to IEC Closed, Shock Direction: B1 25 g 60068-2-27: Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1 Ambient Air Temperature: Close to Contactor for Storage -60...+80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C Technical UL/CSA General Use Rating UL/CSA: (600 V AC) 50 A Horsepower Rating UL/CSA: (120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 5 Hp (200 ... 208 V AC) Three Phase 10 Hp (220 ... 240 V AC) Three Phase 10 Hp (440 ... 480 V AC) Three Phase 20 Hp (550 ... 600 V AC) Three Phase 25 Hp Tightening Torque UL/CSA: Control Circuit 11 inlb Main Circuit 22 inlb Certificates and Declarations (Document Number)