AF38-30-00-11 General Information Extended Product Type: AF38-30-00-11 Product ID: 1SBL297001R1100 EAN: 3471523111516 Catalog Description: AF38-30-00-11 24-60V50/60HZ 20-60VDC Contactor Long Description: AF38 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min.. Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Note: AF..-30-..-11 not suitable for a direct control by PLC- output. AF..-30-..-11 contactor type available in some countries: please consult your ABB representative. Categories Products Low Voltage Products and Systems Control Products Contactors Block Contactors Ordering Minimum Order Quantity: 1 piece Customs Tariff Number: 85369085 EAN: 3471523111516 Dimensions Product Net Depth: 86 mm Product Net Height: 86 mm Product Net Weight: 0.310 kg Product Net Width: 45 mm Container Information Package Level 1 Width: 87 mm Package Level 1 Length: 87 mm Package Level 1 Height: 47 mm Package Level 1 Gross Weight: 0.31 kg Package Level 1 EAN: 3471523111516 Package Level 2 Units: 45 piece Package Level 2 Width: 250 mm Package Level 2 Length: 300 mm Package Level 2 Height: 315 mm Package Level 3 Units: 1080 piece Package Level 1 Units: 1 piece Technical Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 0 Number of Auxiliary Contacts NC: 0 Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14 Rated Operational Voltage: Main Circuit 690 V Rated Frequency (f): Main Circuit 50 / 60 Hz Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 C 50 A Current (I ): th Rated Operational Current AC-1 (I ): (690 V) 40 C 50 A e (690 V) 60 C 42 A (690 V) 70 C 37 A Rated Operational Current AC-3 (I ): (220 / 230 / 240 V) 60 C 40 A e (380 / 400 V) 60 C 38 A (415 V) 60 C 38 A (440 V) 60 C 38 A (500 V) 60 C 33 A (690 V) 60 C 24 ARated Operational Power AC-3 (P ): (220 / 230 / 240 V) 11 kW e (380 / 400 V) 18.5 kW (400 V) 18.5 kW (415 V) 18.5 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW Rated Short-time Withstand Current at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 350 A (I ): at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 50 A cw at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 700 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 225 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A Maximum Electrical Switching AC-1 600 cycles per hour Frequency: AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour Rated Insulation Voltage (U): acc. to UL/CSA 600 V i acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage 6 kV (U ): imp Maximum Mechanical Switching 3600 cycles per hour Frequency: Rated Control Circuit Voltage (U ): 50 Hz 24 ... 60 V c 60 Hz 24 ... 60 V DC Operation 20 ... 60 V Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 1.5...10 mm Flexible with Insulated Ferrule 2x 1.5...4 mm Flexible with Ferrule 1/2x 1.5...10 mm Rigid 1/2x 2.5...10 mm Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm Wire Stripping Length: Control Circuit 10 mm Main Circuit 14 mm Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type: Screw Terminals Number of Main Contacts NO: 3 Environmental Climatic Withstand: Category B according to IEC 60947-1 Annex Q Maximum Operating Altitude 3000 m Permissible: Resistance to Vibrations acc. to IEC 5 ... 300 Hz 4 g closed position / 2 g open position 60068-2-6: Resistance to Shock acc. to IEC Closed, Shock Direction: B1 25 g 60068-2-27: Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1 Ambient Air Temperature: Close to Contactor for Storage -60...+80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C Technical UL/CSA General Use Rating UL/CSA: (600 V AC) 50 A Horsepower Rating UL/CSA: (120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 5 Hp (200 ... 208 V AC) Three Phase 10 Hp (220 ... 240 V AC) Three Phase 10 Hp (440 ... 480 V AC) Three Phase 25 Hp (550 ... 600 V AC) Three Phase 30 Hp Tightening Torque UL/CSA: Control Circuit 11 inlb Main Circuit 22 inlb Certificates and Declarations (Document Number)