Data Sheet GE TM PicoTLynx 6A: Non-Isolated DC-DC Power Modules 2.4Vdc 5.5Vdc input 0.6Vdc to 3.63Vdc output 6A Output Current Features Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 (Z versions) Compatible in a Pb-free or SnPb reflow environment (Z versions) Compliant to REACH Directive (EC) No 1907/2006 Wide Input voltage range (2.4Vdc-5.5Vdc) Output voltage programmable from 0.6Vdc to 3.63 Vdc via external resistor TM Tunable Loop to optimize dynamic output voltage response TM EZ-SEQUENCE RoHS Compliant Flexible output voltage sequencing EZ-SEQUENCE APTH versions Applications Remote sense Distributed power architectures Fixed switching frequency Intermediate bus voltage applications Output overcurrent protection (non-latching) Telecommunications equipment Overtemperature protection Servers and storage applications Cost efficient open frame design Networking equipment Remote On/Off Industrial Equipment Ability to sink and source current Small size: Vin+ Vout+ VIN VOUT 12.2 mm x 12.2 mm x 7.25 mm SENSE (0.48 in x 0.48 in x 0.29 in) RTUNE MODULE Wide operating temperature range (-40C to 85C) SEQ Cin ANSI/UL* 62368-1 and CAN/ CSA C22.2 No. 62368-1 Co CTUNE Recognized, DIN VDE 0868-1/A11:2017 (EN62368- ON/OFF TRIM 1:2014/A11:2017) Q1 RTrim ISO** 9001 and ISO 14001 certified manufacturing GND facilities Description TM The Pico TLynx 6A power modules are non-isolated dc-dc converters that can deliver up to 6A of output current. These modules operate over a wide range of input voltage (V = 2.4Vdc-5.5Vdc) and provide a precisely regulated output voltage from 0.6Vdc to IN 3.63Vdc, programmable via an external resistor. Features include remote On/Off, adjustable output voltage, over current and TM overtemperature protection, and output voltage sequencing (APTH versions). A new feature, the Tunable Loop , allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards 2017 General Electric Corporation. All rights February 17, 2021 reserved. Data Sheet GE TM PicoTLynx 6A: Non-Isolated DC-DC Power Modules 2.4Vdc 5.5Vdc input 0.6Vdc to 3.63Vdc output 6A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V -0.3 6 Vdc IN Continuous Sequencing Voltage APTH V -0.3 V Vdc SEQ iN, Max Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 2.4 5.5 Vdc IN Maximum Input Current All IIN,max 6.5 Adc (VIN=2.4V to 5.5V, IO=IO, max ) Input No Load Current V = 0.6 Vdc I 30 mA O,set IN,No load (VIN = 5.0Vdc, IO = 0, module enabled) VO,set = 3.3Vdc IIN,No load 75 mA Input Stand-by Current All I 2.2 mA IN,stand-by (VIN = 5.0Vdc, module disabled) 2 2 Inrush Transient All I t 1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance V =0 to 5.5V All 25 mAp-p IN , I = I See Test Configurations) O Omax Input Ripple Rejection (120Hz) All 40 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information.