Data Sheet GE TM 9-36V ProLynx 3A: Non-Isolated DC-DC Power Modules 9Vdc 36Vdc input 3Vdc to 18Vdc output 3A to 1.5A Scaled output current 1 9Vdc 24Vdc input -3.3Vdc to -12Vdc output , 3A to 0.7A Scaled output current Features Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 Compliant to REACH Directive (EC) No 1907/2006 Compatible in a Pb-free or SnPb reflow environment (Z versions) Extra Wide Input voltage range (9Vdc36Vdc) Output voltage programmable from 3Vdc to 18 Vdc via external resistor TM Tunable Loop to optimize dynamic output voltage response RoHS Compliant Patent Pending AutoLimit automatic scaling of current limit with output voltage Applications Output overcurrent protection (non-latching) Industrial equipment Overtemperature protection Distributed power architectures Remote On/Off Intermediate bus voltage applications Remote Sense Telecommunications equipment Small size: 20.3 mm x 11.4 mm x 8.5 mm (0.8 in x 0.45 in x 0.335 in) Wide operating temperature range (-40C to 85C) ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 Recognized, DIN VDE 0868-1/A11:2017 (EN62368- Vin+ Vout+ 1:2014/A11:2017) VIN VOUT VS+ ISO** 9001 and ISO 14001 certified manufacturing facilities RTUNE MODULE Cin Co R CTUNE ON/OFF TRIM Q1 RTrim GND Description TM The 9-36V ProLynx series of power modules are non-isolated dc-dc converters that can deliver up to 3A of output current. These modules operate over an extra wide range of input voltage (V = 9Vdc36Vdc) and provide a precisely regulated output voltage IN from 3Vdc to 18Vdc, programmable via an external resistor. Two new features added with this family of products are the ability to externally tune the voltage control loop and a variable current limit inversely dependent on output voltage. Other features include TM remote On/Off, adjustable output voltage, over current and overtemperature protection. The Tunable Loop , allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area and AutoLimit enables the module to deliver the max possible output power across the entire voltage range. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards 1 Output range linked to input voltage range see page 24 February 17, 2021 2015 General Electric Company. All rights reserved. Data Sheet GE TM 9-36V ProLynx 3A: Non-Isolated DC-DC Power Modules 9Vdc 36Vdc input 3Vdc to 18Vdc output 3A to 1.5A Scaled output current 9Vdc 24Vdc input -3.3Vdc to -12Vdc output 3A to 0.7A Scaled output current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All VIN -0.3 37 Vdc Continuous Operating Ambient Temperature All TA -40 85 C (see Thermal Considerations section) Storage Temperature All Tstg -55 125 C Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 9 36 Vdc Maximum Input Current All IIN,max 2 Adc (VIN=9V to 36V, IO=IO, max ) Input No Load Current (V = 28V, I = 0, module enabled) V = 3Vdc I 22 mA IN O O,set IN,No load (VIN = 28V, IO = 0, module enabled) VO,set = 18Vdc IIN,No load 54 mA Input Stand-by Current All I 1.3 mA IN,stand-by (VIN = 28Vdc, module disabled) 2 2 Inrush Transient All I t 0.5 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance V =0 to 36V All 25 mAp-p IN , I = I See Test Configurations) O Omax Input Ripple Rejection (120Hz) All -41 -54 -69 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 8 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. February 17, 2021 2015 General Electric Company. All rights reserved. Page 2