Data Sheet GE Energy TM 6A Austin MicroLynx II: 12V SMT Non-Isolated DC-DC Power Module 8.3Vdc 14Vdc input 0.75Vdc to 5.5Vdc output 6A Output Current Features RoHS Compliant Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 Compliant to REACH Directive (EC) No 1907/2006 Flexible output voltage sequencing TM EZ-SEQUENCE Delivers up to 6A output current TM High efficiency 89% at 3.3V full load (VIN = 12.0V) EZ-SEQUENCE Small size and low profile: 27.9 mm x 11.4 mm x 7.24 mm (1.10 in x 0.45 in x 0.285 in) Low output ripple and noise Applications High Reliability: Distributed power architectures o Calculated MTBF = 15.3M hours at 25 C Full-load Intermediate bus voltage applications Output voltage programmable from 0.75 Vdc to 5.5Vdc via external resistor Telecommunications equipment Line Regulation: 0.3% (typical) Servers and storage applications Load Regulation: 0.4% (typical) Networking equipment Temperature Regulation: 0.4 % (typical) Enterprise Networks Remote On/Off Latest generation ICs (DSP, FPGA, ASIC) and Microprocessor powered applications Output overcurrent protection (non-latching) Wide operating temperature range (-40C to 85C) ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 Recognized, DIN VDE 0868-1/A11:2017 (EN62368- 1:2014/A11:2017 ISO** 9001 and ISO 14001 certified manufacturing facilities Description TM Austin MicroLynx II 12V SMT (surface mount technology) power modules are non-isolated DC-DC converters that can deliver up to 6A of output current with full load efficiency of 89% at 5.0V output. These modules provide precisely regulated output voltage programmable via external resistor from 0.75Vdc to 5.5Vdc over a wide range of input voltage (V = 8.3 - 14V). The Austin IN TM TM MicroLynx II 12V series has a sequencing feature, EZ-SEQUENCE that enable designers to implement various types of output voltage sequencing when powering multiple voltages on a board. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards August 12, 2020 2012 General Electric Company. All rights reserved. GE Energy Data Sheet TM 6A Austin MicroLynx II: 12V SMT Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input 0.75Vdc to 5.5Vdc output 6A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V -0.3 15 Vdc IN Continuous Sequencing voltage All Vseq -0.3 V Vdc IN,max Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage Vo,set 3.63 V 8.3 12 14 Vdc IN Vo,set > 3.63 V 8.3 12 13.2 Vdc IN Maximum Input Current All IIN,max 4.5 Adc (V = V to V , I =I ) IN IN, min IN, max O O, max Input No Load Current V = 0.75 Vdc I 17 mA O,set IN,No load (V = V , Io = 0, module enabled) V = 5.0Vdc I 100 mA IN IN, nom O,set IN,No load Input Stand-by Current All IIN,stand-by 1.2 mA (V = V , module disabled) IN IN, nom 2 2 Inrush Transient All I t 0.4 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance V to V All 30 mAp-p IN, min IN, max, IO= IOmax See Test configuration section) Input Ripple Rejection (120Hz) All 30 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. August 12, 2020 2012 General Electric Company. All rights reserved. Page 2