Data Sheet GE TM 12V Austin SuperLynx II: SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input 0.75Vdc to 5.5Vdc output 16A Output Current Features RoHS Compliant Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863. Compliant to REACH Directive (EC) No 1907/2006. TM Flexible output voltage sequencing EZ-SEQUENCE Delivers up to 16A output current High efficiency 92% at 3.3V full load (VIN = 12.0V) Small size and low profile: 50.8 mm x 12.7 mm x 8.1 mm TM EZ-SEQUENCE (2.00 in x 0.5 in x 0.32 in) Low output ripple and noise Constant switching frequency (300KHz) Applications High Reliability: Distributed power architectures o Calculated MTBF = 9.2M hours at 25 C Full-load Intermediate bus voltage applications Programmable Output voltage Telecommunications equipment Line Regulation: 0.3% (typical) Servers and storage applications Load Regulation: 0.4% (typical) Networking equipment Temperature Regulation: 0.4 % (typical) Enterprise Networks Remote On/Off Latest generation ICs (DSP, FPGA, ASIC) and Remote Sense Microprocessor powered applications Output overcurrent protection (non-latching) Wide operating temperature range (-40C to 85C) ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 Recognized, DIN VDE 0868-1/A11:2017 (EN62368- 1:2014/A11:2017 ISO** 9001 and ISO 14001 certified manufacturing facilities Description TM Austin SuperLynx II 12V SIP (single in-line package) power modules are non-isolated dc-dc converters that can deliver up to 16A of output current with full load efficiency of 92% at 3.3V output. These modules provide a precisely regulated output voltage programmable via an external resistor from 0.75Vdc to 5.0Vdc over a wide range of input voltage (V = 8.3 IN TM TM 14Vdc). Austin SuperLynx II has a sequencing feature, EZ-SEQUENCE that enable designers to implement various types of output voltage sequencing when powering multiple modules on board. Their open-frame construction and small footprint enable designers to develop cost- and space-efficient solutions. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards August 13, 2020 2016 General Electric Company. All rights reserved. Data Sheet GE TM 12V Austin SuperLynx II: SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input 0.75Vdc to 5.5Vdc output 16A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V -0.3 15 Vdc IN Continuous Sequencing voltage All Vseq -0.3 V Vdc IN,max Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage Vo,set 3.63 V 8.3 12.0 14.0 Vdc IN Vo,set > 3.63 V 8.3 12.0 13.2 Vdc IN Maximum Input Current All IIN,max 10 Adc (V = V to V , I =I ) IN IN, min IN, max O O, max Input No Load Current Vo = 0.75Vdc I 40 mA IN,No load (V = V , Io = 0, module enabled) Vo = 5.0Vdc I 100 mA IN IN, nom IN,No load Input Stand-by Current All IIN,stand-by 2 mA (V = V , module disabled) IN IN, nom 2 2 Inrush Transient All I t 0.4 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance V =10V to 14V, All 30 mAp-p IN IO= IOmax See Test configuration section) Input Ripple Rejection (120Hz) All 30 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 15 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. August 13, 2020 2012 General Electric Company. All rights reserved. Page 2