Data Sheet GE Energy TM 6A Austin MicroLynx II : SIP Non-Isolated DC-DC Power Module 2.4Vdc 5.5Vdc input 0.75Vdc to 3.63Vdc output 6A Output Current Features RoHS Compliant Compliant to RoHS EU Directive 2011/65/EU and amended Directive (EU) 2015/863 Compliant to REACH Directive (EC) No 1907/2006 TM Flexible output voltage sequencing EZ-SEQUENCE Delivers up to 6A output current High efficiency 96% at 3.3V full load (V = 5.0V) IN Small size and low profile: 25.4 mm x 12.7mm x 6.68 mm TM (1.00 in x 0. 5 in x 0.263 in) EZ-SEQUENCE Low output ripple and noise High Reliability: Applications o Calculated MTBF = 12.8M hours at 25 C Full-load Distributed power architectures Programmable Output voltage Intermediate bus voltage applications Line Regulation: 0.3% (typical) Telecommunications equipment Load Regulation: 0.4% (typical) Servers and storage applications Temperature Regulation: 0.4 % (typical) Networking equipment Remote On/Off Enterprise Networks Output overcurrent protection (non-latching) Latest generation ICs (DSP, FPGA, ASIC) and Wide operating temperature range (-40C to 85C) Microprocessor powered applications ANSI/UL* 62368-1 and CAN/ CSA C22.2 No. 62368-1 Recognized, DIN VDE 0868-1/A11:2017 (EN62368- 1:2014/A11:2017) ISO** 9001 and ISO 14001 certified manufacturing facilities Description TM Austin MicroLynx II SIP power modules are non-isolated dc-dc converters that can deliver up to 6A of output current with full load efficiency of 96.0% at 3.3V output. These modules provide a precisely regulated output voltage programmable via an TM external resistor from 0.75Vdc to 3.63Vdc over a wide range of input voltage (V = 2.4 5.5Vdc). Austin MicroLynx II has a IN TM sequencing feature, EZ-SEQUENCE that enable designers to implement various types of output voltage sequencing when powering multiple modules on board. Their open-frame construction and small footprint enable designers to develop cost- and space-efficient solutions. In addition to sequencing, standard features include remote On/Off, programmable output voltage and over current protection. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards February 16, 2021 2015 General Electric Company. All rights reserved. Data Sheet GE Energy TM 6A Austin MicroLynxII : SIP Non-Isolated DC-DC Power Modules 2.4Vdc 5.5Vdc input 0.75Vdc to 3.63Vdc output 6A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V -0.3 5.8 Vdc IN Continuous Sequencing voltage All Vseq -0.3 V Vdc IN,max Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage Vo,set 3.63 VIN 2.4 5.5 Vdc Maximum Input Current All IIN,max Adc (VIN= VIN, min to VIN, max, IO=IO, max ) 6.0 Input No Load Current VO,set = 0.75 Vdc IIN,No load 20 mA (VIN = VIN, nom, Io = 0, module enabled) VO,set = 3.3Vdc IIN,No load 45 mA Input Stand-by Current All IIN,stand-by 0.6 mA (V = V , module disabled) IN IN, nom 2 2 Inrush Transient All I t 0.04 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance V to V All 35 mAp-p IN, min IN, I = I See Test configuration section) max, O Omax Input Ripple Rejection (120Hz) All 30 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. GE 2