Data Sheet GE CAR0424FP front-end Input: 90Vac to 264Vac Output: 24Vdc 400W 5Vdc 1A Standby Features Efficiency: exceeds 80plus Gold criteria Universal input with PFC No power de-rating at low range input ON/OFF control of the 24Vdc output Remote sense on the 24Vdc output No minimum load requirements 5Vdc 1A Standby Auto recoverable OC & OT protection Operating temperature: 0 - 70C (de-rated above 50 C) Provisions for securing the power supply from either side Applications or the bottom Forced air cooling 24Vdc distributed power architectures EN60950-1 2006 +A12,2011 Routers/ VoIP/Soft and other Telecom Switches UL60950-1, 2007 Mid to high-end Servers, ATE Equipment IEC60950-1, 2005 +A1:2009 +A2:2013 CE mark CB certificate available Meets FCC part 15, EN55022 Class B standards Meets EN61000 immunity and transient standards Shock & vibration: Meets IPC 9592 Class II standards Description The CAR0424FP Front-End provides highly efficient isolated power from worldwide input mains in a compact form factor. This power supply is ideal for applications where mid to light load efficiency is of key importance in order to reduce system power consumption during typical operational conditions. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. Intended for integration into end-user equipment. All the required procedures for CE marking of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards. March 25, 2015 2015 General Electric Company. All rights reserved. Data Sheet GE CAR0424FP front-end Input: 90Vac to 264Vac Output: 24Vdc 400W 5Vdc 5W Standby Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Symbol Min Max Unit Input Voltage: Continuous V 0 264 V IN AC 1 Operating Ambient Temperature T 0 70 C A Storage Temperature Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) 2121 V DC Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions. INPUT Parameter Symbol Min Typ Max Unit Operational Range V 90 115/230 264 V IN AC F IN Frequency Range (ETSI 300-132-1 recommendation) 47 50/60 63 Hz Main Output Turn OFF 70 80 Main Outptut Turn ON VIN 75 85 VAC Hysteresis between turn OFF and turn ON 5 Maximum Input Current (VO= VO, set, IO=IO, max) VIN= 100VAC 4.6 IIN AAC 2.2 VIN= 208VAC Cold Start Inrush Current (Excluding x-caps, 25C, <10ms, I 37 A IN PEAK per ETSI 300-132) Efficiency (T =25C, V = 24V) VIN 115V / 230V amb O % 100% load 88 / 91 T 20 ms Holdup time (VOUT 23.52VDC, TAMB 25C, IO=IO, max) Vin= 230VAC Leakage Current (VIN= 250VAC, FIN = 60Hz) IIN 3.5 mARMS Isolation Input/Output 3000 V AC Input/Frame 2121 V DC Output/Frame 100 VDC 24V MAIN OUTPUT dc Parameter Symbol Min Typ Max Unit 2 Output Power fan cooled 400 W 0 - W convection cooled 300 Factory Set default set point (full load, 115VAC, 25C) 23.95 24.00 24.05 VDC Overall regulation (Line, load, temperature) -2 +2 % 3 Ripple and noise 120 mVP-P V O Turn-ON overshoot +3.5 % Turn-ON delay 2 sec ON/OFF delay time 40 ms Turn-ON rise time (10 90% of V ) 500 ms OUT 1 See accompanying power derating table 2 450W for 1 minute, 10% duty cycle max 3 Measured across a 10f tantalum and a 0.1f ceramic capacitors in parallel. 20MHz bandwidth Page 2 March 25, 2015 2015 General Electric Company. All rights reserved.