CAR1612FP Series by Lineage Power 1600 Watt +12V Front End Power Supply Features: Compact 1U Profile High Efficiency design optimized for mid to light load applications Constant Current Characteristic N+1 Redundancy with Hot Plug Capability High Power Density (20W/in3) 3.3VSB, Active Load Sharing, IC and PMBus standard Interface Remote On/Off and Remote Sense functions PLATINUM FEATURES BENEFITS KEY MARKET SEGMENTS & APPLICATIONS 3 High Power Density 20W/in More system space for application circuits and hardware Distributed Power Blade Servers Load Sharing & Fault Tolerant Excellent reliability in N+1 operation Mid-End Servers Network Equipment Automatic Fan Speed Control Reduces audible noise and increases reliability System Scalability up to 6.4kW Allows flexibility with minimum investment Network Attached Storage Universal Input & International Reduces logistical costs Storage Area Networks Certifications SPECIFICATIONS 1600 Watt +12V Front End Power Supply Input Voltage Range 85-264 VAC, 47-63 Hz, derate to 1200W for <180VAC Input Input Current Maximum 10.5A 180VAC / 14.3A 100VAC, Full Load (max) Inrush Current 40A max. cold start (per ETS 300 132-1 and Bellcore specifications) Input Protection 20 Amp / 250 VAC Power Factor 0.99 typical at full load, complies with IEC555, EN60555-2, EN61000-3-2 Efficiency Up to 94.5% at 50% Load and 230VAC Operation Output Power 1600W at High Line Operation (180-264 VAC), 1200W at Low Line Operation (85-132 VAC) Output Voltage Range 10.8~13.2 VDC with remote programming Output Current 134A 12Vout / 230VAC Operation, 100A 12Vout / 110VAC Operation Standby Bias Voltage 3.3VSB 1A (optional 5Vsb) Voltage Regulation 2% of Vnom for any combination of line, load and temperature Output Ripple & Noise 1% (pk-pk) 20MHz with 0.1F ceramic and 10F Tantalum caps at the output Transient Response 5% max deviation Recovery time 300s 50% load step and di/dt < 1A/s Hold-Up Time 12ms at 1600W (typical) 220Vac (Early Warning: 2ms) Remote On/Off ON if >3V or open OFF if <1V (max. sink 1mA) Open collector type Current Limit Protection Adjustable via IC interface or PMBus, Constant current characteristic & power limited to 1600W or 1200W (<180VAC input) Short Circuit Protection Self protected with auto recovery Over Voltage Protection Trip level >+14.8Vdc 1V, Reset condition by recycling the AC input or applying Remote ON/OFF Operating Temperature -10C to +70C. power derating above 50C at 2.5%/C Over Temperature Protection Non-Latching, thermal shutdown point is set for 125C and recovery point is 110C EMI FCC-B & EN55022-B with specified filter or at rack level, GR-1089-CORE LED Indicators AC OK (Green) / DC OK (Green) / Thermal Alarm (Orange) / Fault (Red), All on one LED Tri-color LED Analog Status & Control Voltage Programming (V Prog), Load sharing (I Share), Remote On/Off, Current Monitor (I Monitor), AC OK, DC OK, Temperature Warning, Fault, PS Present, Module Enable, 2 Digital Status & Control I C Option and PMBus Option, see detailed specification for details Shock & Vibration NEBS GR-63-CORE Level 3 Dimensions 12.45 x 4.00 x 1.61 / 316.23 x 101.6 x 41.91mm Weight 4.28 lb. / 1.94 kg. Safety Approvals IEC/UL/CSA/EN60950-1, CE Mark (LVD), TUV Options 5VSB Output, Bezel www.LineagePower.com Lineage Power Lineage Power Lineage Power (China) 3000 Skyline Dr. P: (972) 284-2000 2841 Dow Avenue P: (714) 544-6665 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Mesquite, TX 75149 F: (972) 284-2000 Tustin, CA 92780 USA F: (714) 838-4742 Shanghai, 201401 China P: 021 6710 8910 rev 100603CAR1612FP Series by Lineage Power 1600 Watt +12V Front End Power Supply OUTLINE DRAWING All Dimensions in Inches (mm) Tolerance: .XX = .02 in (.50 mm) .XXX = .010 in (.254 mm) EFFICIENCY CURVE: CONNECTOR DRAWING: 94.5% 94.5% 94.0% 95% 93.4% 92.5% 92.4% 93% D1 D2 D3 D4 D5 D6 91% C1 C2 C3 C4 C5 C6 P8 89% P1 P2 P3 P4 P5 P6 P7 88.5% B1 B2 B3 B4 B5 B6 87% A1 A2 A3 A4 A5 A6 85% 83% 81% FCI Berg Pt 51732-021 or equivalent 79% Suggested mating connector part 51762-10802400ABLF (Right Angle Mounting) 10% 20% 40% 50% 60% 80% 100% % of Load 230Vac PIN OUT INFORMATION PART NUMBER DEFINITION GUIDE: A1 VSB 3.3V B4 PS Present D1 V Prog P4 Vout Return CAR 16 12 F P x xx -1A A2 VSB 3.3V Return B5 SDA D2 OVP Test Point P5 Vout Series Rev. A3 Signal RTN B6 SCL D3 Remote On/Off P6 Vout 16=1600W Blank=Non-compliant Output Current YO=5 of 6 Compliant A4 Write Protect C1 I Share D4 DC OK P7 Vout ZO=6 of 6 Compliant 12=12V RoHS A5 Remote Sense (+) C2 Not Connected D5 AC OK P8 Vout Output Voltage B=Bezel Option F=Front End A6 Remote Sense (-) C3 Temp Warning D6 Interrupt Blank=None Type P=Positive Options Example: B1 Fault C4 I2C Address (A0) P1 Vout Return Polarity B2 I Monitor C5 I2C Address (A1) P2 Vout Return CAR1612FPBZ0-1A 1600W/12V Front End, Bezel, 6 of 6 RoHS B3 Enable (Short Pin) C6 I2C Address (A2) P3 Vout Return www.LineagePower.com Lineage Power Lineage Power Lineage Power (China) 3000 Skyline Dr. P: (972) 284-2000 2841 Dow Avenue P: (714) 544-6665 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Mesquite, TX 75149 F: (972) 284-2000 Tustin, CA 92780 USA F: (714) 838-4742 Shanghai, 201401 China P: 021 6710 8910 rev 100603 Efficiency %