Data Sheet GE Energy CAR2024FP series rectifier Input: 90Vac to 264Vac Output: 24Vdc 83A 3.3Vdc or 5 Vdc 1A Features Universal input with PFC Constant power characteristic 3 front panel LEDs: input, output, fault Remote ON/OFF control of the 24Vdc output Remote sense on the 24Vdc output No minimum load requirements Redundant parallel operation Active load sharing (single wire) Hot Plug-ability Efficiency: typically 90% 50% load Applications Standby orderable either as 3.3Vdc or 5Vdc 24Vdc distributed power architectures Auto recoverable OC & OT protection Telecom Base Stations Operating temperature: -10 - 70C (de-rated above Mid to high-end Servers 50C) 2 Digital status & control: I C and PMBus serial bus Enterprise Networking nd EN/IEC/UL60950-1 2 edition UL, CSA and VDE Network Attached Storage EMI: class A FCC docket 20780 part 15, EN55022 Telecom Access Nodes Meets EN6100 immunity and transient standards Routers/Switches Shock & vibration: NEBS GR-63-CORE, level 3 Broadband Switches Operation at 4000m altitude ATE Equipment Description The CAR2024FP series of Front-End rectifiers provide highly efficient isolated 2000 watts 24Vdc power from worldwide 3 input mains in a compact 1U industry standard form factor in an unprecedented power density of 21W/in . These rectifiers are ideal for either datacom or telecom applications such as enterprise networking, remote base stations, mid to high-end servers, and storage equipment, where mid to light load efficiency is of key importance given the nature of the power consumption of the end application. The high-density, front-to-back airflow is designed for minimal space utilization and is highly expandable for future 2 growth. The industry standard PMBus compliant I C communications buss offers a full range of control and monitoring capabilities. The SMBAlert signal pin alerts customers automatically of any state change within the power supply. August 21, 2019 2012 General Electric Company. All rights reserved. GE Energy CAR2024FP series rectifier Input: 90Vac to 264Vac Output: 24 Vdc 83A 3.3Vdc or 5 Vdc 1A Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage: Continuous All VIN 0 264 Vac 1 Operating Ambient Temperature All TA -10 70 C Storage Temperature All Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) All 1500 Vac Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions. INPUT Parameter Device Symbol Min Typ Max Unit Operational Range All V 90 110/230 264 V IN ac F IN Frequency Range (ETSI 300-132-1 recommendation) All 47 50/60 63 Hz V IN Main Output Turn OFF All 85 V ac Maximum Input Current V = 100V IN ac 14.3 All IIN Aac 12.6 (VO= VO, set, IO=IO, max) VIN= 180Vac Cold Start Inrush Current All I 40 A IN peak (Excluding x-caps, 25C, <10ms, per ETSI 300-132) Efficiency 100% load 90 All 90 % (T =25C, V = 230V , V = 24Vdc, I =I ) 50% load amb in ac out O O, max 84 20% load All Power Factor (Vin=230Vac, IO=IO, max) PF 0.99 2 Holdup time Vin= 220Vac 15 All T ms 15 (Vout= 24Vdc, Tamb 25 C, IO=IO, max) Vin= 100Vac All Early warning prior to loss of DC output below regulation 3 ms All Ride through T 10 ms All Leakage Current (Vin= 250Vac, Fin = 60Hz) IIN 3 mArms Isolation Input/Output 3000 Vac Input/Frame All 1500 Vac Output/Frame 100 Vdc 24V MAIN OUTPUT dc Parameter Device Symbol Min Typ Max Unit Output Power HL / LL 180 264 / 90-132 Vac Vdc 24Vdc 0 - 2000/1200 W All W Vdc = 21Vdc 0 - 1743/1050 W Set point All 23.976 24.00 24.024 Vdc All Overall regulation (load, temperature, aging) -3 +3 % Remote sense voltage drop (both sense wires) 0.5 Vdc V out 3 All Ripple and noise 240 mV p-p All Turn-ON overshoot +3 % 1 Derated above 50C at 2.5%/C 2 24V output can decay down to 20V 3 Measured across a 10f electrolytic and a 0.1f ceramic capacitors in parallel. 20MHz bandwidth August 21, 2019 2012 General Electric Company. All rights reserved. Page 2