Data Sheet GE CP2000AC54TE Compact Power Line High Efficiency Rectifier 100-120/200-277V input Default Outputs: 54V 2000W, 5V 4W AC DC DC Features RoHS Compliant Efficiency 96.2% 3 Compact 1RU form factor with 30 W/in density Constant power from 52 58V DC 2000W from nominal 200 277V AC 1200W from nominal 100 120V AC Output voltage programmable from 42V 58V DC 2 PMBus compliant dual I C and RS485 serial busses 2 Isolated +5V Aux, signals and I C communications Power factor correction (meets EN/IEC 61000-3-2 and EN 60555-2 requirements) Applications Output overvoltage and overload protection 48V distributed power architectures DC AC Input overvoltage and under voltage protection Routers/Switches Over-temperature warning and protection VoIP/Soft Switches Redundant, parallel operation with active load sharing LAN/WAN/MAN applications Remote ON/OFF File servers Internally controlled Variable-speed fan Indoor wireless Hot insertion/removal (hot plug) Telecommunications equipment Four front panel LED indicators Enterprise Networks UL* Recognized to UL60950-1, CAN/ CSA C22.2 No. SAN/NAS/iSCSI applications 60950-1, and VDE 0805-1 Licensed to IEC60950-1 CE mark meets 2006/95/EC directive RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 Description The CP2000AC54TE Rectifier provides significant efficiency improvements in the Compact Power Line platform of Rectifiers. High- density front-to-back airflow is designed for minimal space utilization and is highly expandable for future growth. The wide-input 2 standard product is designed to be deployed internationally. It is configured with both RS485 and dual-redundant I C communications busses that allow it to be used in a broad range of applications. These signals and the 5V auxiliary supply are isolated from the main output and frame ground. Feature set flexibility makes this rectifier an excellent choice for applications requiring modular AC to - 48V DC intermediate voltages, such as in distributed power. August 17, 2020 2020 General Electric Company. All rights reserved. Data Sheet GE CP2000AC54TE CPL High Efficiency Rectifier 100-120/200-277V input Default Outputs: 54V 2000W, 5V 4W AC DC DC * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment. All CE marking procedures of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards + The PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF) Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Symbol Min Max Unit Input Voltage: Continuous VIN 0 300 V AC 1 Operating Ambient Temperature TA -10 75 C Storage Temperature Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) 1500 V AC Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, Vo=54V , resistive load, and temperature conditions. DC INPUT Parameter Symbol Min Typ Max Unit Startup Input Voltage Low-line Operation VIN 90 VAC High-line Operation 185 Operating Voltage Range Low-line Configuration VIN 90 100 120 140 VAC High-line Configuration 185 200 - 277 300 Input Voltage Swell (no damage) 305 Input Frequency F 47 66 Hz IN 11.9 Input Current at 110VAC IIN AAC at 240VAC 8.8 Inrush Transient (at 25C, excluding X-Capacitor charging) I 25 30 A IN PK Idle Power (at 220V ) 54V OFF 8.2 AC PIN W 54V ON Io=0 16 Input Leakage Current (265VAC, 60Hz) IIN 2.5 3.5 mA Power Factor (50 100% load) PF 0.96 0.995 2 94.5 96.2 % Efficiency (40 90% of FL, 240VAC 25 C) Holdup time (output allowed to decay down to 40V ) 20 DC T ms For loads below 1200W 30 Ride thru (tested at 115V 230V. (Complies to CISPR24) T 1/2 1 cycle 3 Power Fail Warning (main output allowed to decay to 40V ) PFW 3 5 ms DC Isolation (per EN60950) (consult factory for testing to this requirement) Input-Chassis/Signals V 1500 V AC Input - Output 3000 V AC 1 See the derating guidelines under the Environmental Specifications section 2 See efficiency curve in the Characteristics Curves section. 3 Internal protection circuits may override the PFW signal and may trigger an immediate shutdown. August 17, 2020 2020 General Electric Company. All rights reserved. Page 2