Data sheet GE CP3000/3500AC54TE Global Platform High Efficiency Rectifier Input: 100-120/200-277 Vac Default Output: 54 Vdc 3000W/3500W 5 Vdc 10W Features RoHS Compliant Efficiency meets 80plus Titanium requirements 3 Compact 1RU form factor with 40 W/in density Constant power from 52 58V DC 3000 or 3500W from nominal 200-277V AC 1500W from nominal 100 120V AC Output voltage programmable from 42V 58V DC ON/OFF control of the main output Comprehensive input, output and overtemp. protection 2 PMBus compliant dual I C serial bus and RS485 Precision measurement reporting such as input power Applications consumption, input/output voltage & current 48V distributed power architectures DC Remote firmware upgrade capable Routers/ VoIP/Soft and other Telecom Switches Power factor correction (meets EN/IEC 61000-3-2 and LAN/WAN/MAN applications EN 60555-2 requirements) File servers, Enterprise Networks, Indoor wireless Redundant, parallel operation with active load sharing SAN/NAS/iSCSI applications Redundant +5V 2A Aux power Internally controlled Variable-speed fan Hot insertion/removal (hot plug) Four front panel LED indicators UL and cUL approved to UL/CSA 62368-1, TUV (EN62368- 1), CE Mark (for LVD) and CB Report available RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 Compliant to REACH Directive (EC) No 1907/2006 Description The CP3000/3500AC54TEP Rectifiers provide significantly higher power density in the same form factor and efficiency improvements in the Compact Power Line of Rectifiers. The only difference between these rectifiers is output power limit. High-density front-to-back airflow is designed for minimal space utilization and is highly expandable for future growth. Wide-input enables the rectifier to be 2 deployed internationally into a wide range of commercially available voltage sources. Configured with both dual-redundant I C and RS485 based communications busses, so that it could be positioned into a broad range of applications. Feature set flexibility makes this rectifier an excellent choice for applications requiring modular AC to - 48V intermediate voltages, such as in distributed power. DC * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment. All CE marking procedures of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards + The PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF) November 19, 2020 2020 General Electric Company. All rights reserved. Data sheet GE CP3000/3500AC54TE Global Platform High Efficiency Rectifier Input: 100-120/200-277 Vac Default Output: 54 Vdc 3500W 5 Vdc 10W Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Symbol Min Max Unit Input Voltage: Continuous V 0 300 V IN AC 1 Operating Ambient Temperature T -10 75 C A Storage Temperature Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) 1500 VAC Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, Vo=54V , resistive load, and temperature DC conditions. INPUT Parameter Symbol Min Typ Max Unit Startup Voltage Low-line Operation 80 85 90 High-line Operation 185 Operating Voltage Range Low-line Configuration 90 100 120 140 VIN VAC High-line Configuration 185 200 - 277 300 Voltage Swell (no damage) 305 Turn OFF Voltage 75 80 85 Hysteresis 5 Frequency FIN 47 66 Hz Source Impedance (NEC allows 2.5% of source voltage drop inside a 0.2 building) 15.5 Operating Current at 110VAC IIN AAC at 240VAC 16 Inrush Transient (220V , 25C, excluding X-Capacitor charging) I 25 40 A RMS IN PK 9 Idle Power (at 240VAC, 25C) 54V OFF P W IN 54V ON Io=0 18 Leakage Current (300VAC, 60Hz) IIN 2.5 3.5 mA Power Factor (50 100% load) PF 0.97 0.995 2 90 Efficiency , 240VAC 25 C 10% of FL 20% of FL 94 % 50% of FL 96 FL 91 10 Holdup time (output allowed to decay down to 40VDC) T ms For loads below 1500W 15 T 1/2 1 cycle Ride through (at 240VAC, 25C) 3 Power Good Warning (main output allowed to decay to 40VDC) PG 3 5 ms Isolation (per EN62368-1) (consult factory for testing to this requirement) Input-Chassis/Signals V 1500 VAC Input - Output 3000 VAC 1 See the derating guidelines under the Environmental Specifications section 2 Fan disabled, 5V output at 0 load. 3 Internal protection circuits may override the PG signal and may trigger an immediate shutdown. PG should not indicate normal (HI) until the main output is within regulation. PG should be asserted if the main output is about to shut down for any detectible reason. November 19, 2020 2020 General Electric Company. All rights reserved. Page 2