Data Sheet GE EHHD006A0B Hammerhead* Series DC-DC Converter Power Modules 18-75Vdc Input 12Vdc, 6.0A, 72W Output Features Compliant to RoHS II EU Directive 2011/65/EU (-Z versions) Compliant to REACH Directive (EC) No 1907/2006 Flat and high-efficiency curve Industry standard, DOSA compliant footprint 57.9mm x 22.8mm x 7.6mm (2.28 in x 0.9 in x 0.30 in) Low-profile height and reduced component skyline Ultra-wide input voltage range: 18-75 V dc Tightly regulated output Remote sense Output voltage adjust: 90% to 110% of V O,nom RoHS Compliant Constant switching frequency Positive remote On/Off logic Applications Input under/overvoltage protection Distributed Power Architectures Output overcurrent and overvoltage protection Wireless Networks Overtemperature protection Access and Optical Network Equipment No reverse current during output shutdown Wide operating temperature range (-40C to 85C) Industrial Equipment Suitable for cold wall cooling using suitable Gap Pad applied directly to top side of module ANSI/UL 60950-1-2011 and CAN/CSA C22.2 No. 60950-1- 07, Second Edition + A1:2011 (MOD), dated March 19, 2011 and DIN EN 60950-1 (VDE 0805 Teil 1):2011-01 EN 60950- Options 1:2006 + A11:2009 + A1:2010, DIN EN 60950-1/A12 (VDE Negative Remote On/Off logic (preferred) 0805-1/A12):2011-08 EN 60950-1/A12:2011-02, IEC 60950- 1(ed.2) am1:2009 Overcurrent/Overtemperature/Overvoltage protections (Auto-restart) (preferred) CE mark meets 2006/95/EC directive Heat plate version (-H) Meets the voltage and current requirements for ETSI 300- 132-2 and complies with and licensed for basic insulation Surface Mount version (-S) rating per EN60950-1 2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE standards ** ISO 9001 and ISO 14001 certified manufacturing facilities Description The EHHD006A0B Series, eighth-brick, low-height power modules are isolated DC-DC converters that provide a single, precisely regulated output voltage over an ultra-wide input voltage range of 18-75V . The EHHD006A0B provides 12V nominal output dc dc voltage rated for 6Adc output current. The module incorporates GEs vast heritage for reliability and quality, while also using the latest in technology and component and process standardization to achieve highly competitive cost. The open frame module construction, available in both surface mount and through-hole packaging, enables designers to develop cost and space efficient solutions. The module achieves typical full load efficiency greater than 92% at VIN=24Vdc and greater than 90% at VIN=48Vdc. Standard features include remote On/Off, remote sense, output voltage adjustment, overvoltage, overcurrent and overtemperature protection. An optional heat plate allows for external standard, eighth-brick heat sink attachment to achieve higher output current in high temperature applications. * Trademark Of General Electric Company UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed. IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards July 12, 2013 2012 General Electric Company. All rights reserved. Page 1 Data Sheet GE EHHD006A0B Hammerhead Series DC-DC Converter Power Modules 18-75Vdc Input 12Vdc, 6.0A, 72W Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All VIN -0.3 80 Vdc Transient, operational (100 ms) All VIN,trans -0.3 100 Vdc Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Altitude All 4000 m I/O Isolation Voltage (100% factory Hi-Pot tested) All 2250 V dc * For higher altitude applications, contact your GE Sales Representative for alternative conditions of use. Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 18 24/48 75 V IN dc Maximum Input Current All IIN 4.4 5.0 Adc (V = V to V , V = V , I =I ) IN IN, min IN, max O O, set O O, max Input No Load Current All IIN,No load 80 mA (VIN = 48V, IO = 0, module enabled) Input Stand-by Current All I 5 8 mA IN,stand-by (VIN = 48V, module disabled) 2 2 Inrush Transient All It 0.5 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1 H source impedance VIN, min to VIN, max, IO= IOmax See All 30 mAp-p test configuration section) Input Ripple Rejection (120Hz) All 50 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum DC input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. July 12, 2013 2012 General Electric Company. All rights reserved. Page 2