Data Sheet GE EVK011A0B Series (Eighth-Brick) DC-DC Converter Power Modules 3660Vdc Input 12.0Vdc Output 11A Output Current Features RoHS Compliant Compliant to RoHS II EU Directive 2011/65/EU Compliant to REACH Directive (EC) No 1907/2006 Compatible in a Pb-free or SnPb reflow environment High efficiency 95% at 12V full load Industry standard, DOSA compliant, Eighth brick footprint 57.9mm x 22.9mm x 8.95mm (2.28in x 0.90in x 0.352in) Wide Input voltage range: 36-60 Vdc Tightly regulated output Constant switching frequency Applications Positive Remote On/Off logic Distributed Power Architectures Input under/over voltage protection Wireless Networks Output overcurrent/voltage protection Access and Optical Network Equipment Over-temperature protection Enterprise Networks including Power over Ethernet Remote sense (PoE) No minimum load required No reverse current during output shutdown Output Voltage adjust: 80% to 110% of V o,nom Options Operating temperature range (-40C to 85C) Negative Remote On/Off logic UL* 60950-1Recognized, CSA C22.2 No. 60950-1-03 Certified, Over current/Over temperature/Over voltage and VDE 0805:2001-12 (EN60950-1) Licensed protections (Auto-restart) CE mark meets 73/23/EEC and 96/68/EEC directives Meets the voltage and current requirements for ETSI 300-132- 2 and complies with and licensed for Basic insulation rating per EN60950-1 2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE standards ** ISO 9001 and ISO 14001 certified manufacturing facilities * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed. IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards May 15, 2013 2012 General Electric Company. All rights reserved. Page 1 Data Sheet GE EVK011A0B Series (Eighth-Brick) DC-DC Converter Power Modules 3660Vdc Input 12.0Vdc Output 11A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All V -0.3 60 V IN dc Transient (10 ms) All VIN,trans -0.3 75 Vdc Operating Ambient Temperature All TA -40 85 C (see Thermal Considerations section) Storage Temperature All Tstg -55 125 C I/O Isolation voltage (100% factory Hi-Pot tested) All 2250 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 36 48 60 V IN dc Maximum Input Current All I 4.0 4.4 A IN,max dc (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current All I 75 mA IN,No load (V = V , I = 0, module enabled) IN IN, nom O Input Stand-by Current All IIN,stand-by 20 mA (VIN = VIN, nom, module disabled) 2 2 Inrush Transient All It 0.5 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1 H source impedance V to V All 20 mA IN, min IN, p-p I = I See Test configuration section) max, O Omax Input Ripple Rejection (120Hz) All 50 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 8 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. May 15, 2013 2012 General Electric Company. All rights reserved. Page 2