Data Sheet GE EVW010A0B Series (Eighth-Brick) DC-DC Power Modules 36 75Vdc Input 12.0Vdc Output 10A Output Current Features Compliant to RoHS EU Directive 2011/65/EU and amended Directive (EU) 2015/863. (Z versions) Compliant to REACH Directive (EC) No 1907/2006 Compatible in a Pb-free or SnPb reflow environment High efficiency 93.5% at 12V full load Industry standard, DOSA compliant, Eighth brick RoHS Compliant footprint 57.9mm x 22.9mm x 7.8mm (2.28in x 0.90in x 0.31in) Wide Input voltage range: 36-75 Vdc Tightly regulated output Applications Constant switching frequency Positive Remote On/Off logic Distributed Power Architectures Input under/over voltage protection Wireless Networks Output overcurrent/voltage protection Access and Optical Network Equipment Over-temperature protection Enterprise Networks including Power over Ethernet (PoE) Remote sense No minimum load required No reverse current during output shutdown Options Output Voltage adjust: 80% to 110% of V o,nom Negative Remote On/Off logic Operating temperature range (-40C to 85C) Over current/Over temperature/Over voltage protections ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 (Auto-restart) Recognized, DIN VDE 0868-1/A11:2017 (EN62368- Heat plate versions (-H) 1:2014/A11:2017) Surface Mount version (-S) CE mark meets 2014/35/EU directive Meets the voltage and current requirements for ETSI 300-132-2 and complies with and licensed for Basic insulation 2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE standards ** ISO 9001 and ISO 14001 certified manufacturing facilities Description The EVW010A0B, Eighth-brick low-height power module is an isolated dc-dc converters that can deliver up to 10A of output current and provide a precisely regulated output voltage of 12V over a wide range of input voltages (VIN = 36 - 75Vdc). The modules achieve typical full load efficiency of 93.5%. The open frame modules construction, available in both surface-mount and through-hole packaging, enable designers to develop cost and space efficient solutions. Standard features include remote On/Off, remote sense, output voltage adjustment, overvoltage, overcurrent and overtemperature protection. March 18, 2021 2012 General Electric Company. All rights reserved. Data Sheet GE EVW010A0B Series (Eighth-Brick) DC-DC Power Modules 36 75Vdc Input 12.0Vdc Output 10A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All V -0.3 80 V IN dc Transient (100 ms) All V -0.3 100 V IN,trans dc Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg I/O Isolation voltage (100% factory Hi-Pot tested) All 2250 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 36 48 75 V IN dc Maximum Input Current All IIN,max 3.4 3.7 Adc (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current All IIN,No load 75 mA (V = V , I = 0, module enabled) IN IN, nom O Input Stand-by Current All IIN,stand-by 20 mA (V = V , module disabled) IN IN, nom 2 2 Inrush Transient All I t 0.5 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance VIN, min to VIN, All 20 mAp-p max, IO= IOmax See Test configuration section) Input Ripple Rejection (120Hz) All 50 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 8 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. March 18, 2021 2012 General Electric Company. All rights reserved. Page 2