GE Critical Power FLTR100V10 Filter Module 75 Vdc Input Maximum, 10 A Maximum RoHS Compliant The FLTR100V10 Filter Module in low- profile packages, have high and layout, the Lineage Power filter is designed to reduce the interwinding capacitance that can module will significantly reduce the conducted common-mode and increase common-mode current levels. conducted differential and differential-mode noise on input or Also, metal substrates used to facilitate common-mode noise returned to output lines of high-frequency switching heat transfer from the power train the power source. CISPR and FCC power supplies. The module has a components to an external heat sink add class B requirements can be met maximum current rating of 10 A. It to common-mode noise because of the by using the filter as described provides high insertion loss throughout large capacitance between switching in the following sections. the frequency range regulated by the U.S. components and the metal substrate. Federal Communications Commission Common-mode and differential-mode (FCC) and the International Special filtering of power supply dc input and Many international agencies specify Committee on Radio Interference output lines conducted and radiated emissions (CISPR) for conducted emissions. limits for electronic products. Included The module is 51 mm long, 28 mm wide, Computer applications among these are CISPR, FCC, VCCI, and 12 mm high (2.0 in. x 1.1 in. x 0.46 in.) Communications equipment and the new CE specifications. Most and mounts on a PC board in a natural agency-conducted noise limits apply Compliant to RoHS EU Directive convection or forced-air environment. only to noise currents induced onto 2011/65/EU the ac power lines in finished products. Compatible in Pb- free or SnPb European Telecommunication Standard Introduction reflow environment Instructions (ETSI) are an exception, High-density power modules are usually Small size: 51 mm x 28 mm x 12 mm applying CE requirements to dc supplies designed to operate at a high switching (2.0 in. x 1.1 in. x 0.46 in.) with cables over three meters long. frequency to reduce the size of the Although not required to do so by agency Optimized for use with high-frequency internal filter components. The small standards, some system designers apply dc-to-dc power modules EMI filters internal to the modules are the conducted emissions requirements often inadequate to meet stringent Printed-circuit board mountable to subassemblies within the product to international EMI requirements. Many Operating case temperature range: reduce internal interference between high-density electronic packaging 40 C to +100 C subsystems and to reduce the difficulty techniques can increase the noise of meeting overall system requirements. CAN/CSA C22.2 No. 60950-1-07 conducted onto the modules input and / UL* 60950-1, Second Edition, output lines. For example, the close dated March 27, 2007 proximity of switching components to To meet these requirements, external the input pins increases internal noise CE mark meets 73/23/EEC and 93/68/ filtering of the power module is often coupling and planar transformers, EEC directives required. When used in conjunction with designed to handle high-power levels the recommended external components Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. PARAMETER SYMBOL MIN MAX UNIT Input Voltage: VI 75 Vdc Continuous VI, trans 100 V Transient (100 ms) Voltage from GND to Either Input Lead (1 minute) 1500 Vdc Operating Case Temperature Tc -40 100 C Storage Temperature* Tstg 55 125 C * For the processing, handling and storage (module not powered), the filter module can handle -55C to 125C exposure . Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage and temperature conditions. PARAMETER SYMBOL MIN TYP MAX UNIT Resistance per Leg R 14 m Maximum Average Current I max 10 A (TA = 60 C, 2.0 m/s (400 lfm) air) Maximum Average Current I max 6.5 A (TA = 74 C, natural convection) Common-mode Insertion Loss 36 dB (50 circuit, 500 kHz) Differential-mode Insertion Loss 44 dB (50 circuit, 500 kHz) 2 Filter Modules Datasheet www.gecriticalpower.com