Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates UL, CSA Rated insulation voltage Ui V 690 V AC/ 440 V DC Acc. to IEC 158-1, IEC 60 947-4-1, CSA, UL, NEMA Impulse withstand voltage Uimp kV 6 Acc. to IEC 60 947-4-1 Rated operating voltage Ue 690 V AC/ 440 V DC Rated frequency HZ 50/60 Short circuit capacity kA 10/16/30/50 (see table) Rated current range Ie 16 A Tripping class IEC/EN 60947-4-1 10/10 A Tripping factor 12 x In Mechanical life time in operation switches 100.000 Permissible ambient temperature -for storage C -40 ... + 80 -in operation C -25 ... + 55 (70) Climatic resistance acc. to IEC 68-2-3, IEC 68-2-30 Mounting position Horizontal, other on request Disconnecting feature IEC/EN 60947-1 yes Phase failure sensitiveness IEC/EN 60947-1 yes Permissible resistance to vibrations 10 ...100 Hz multiple of g 5 Permissible resistance to shocks 20 Resistance to shock Shock duration ms 20 Terminal types and connecting capacity -Screw terminals (srew size) M3,5 +/- poz. 2 -Connection cross section 2 -single-core or stranded mm 2x1,0x4,0 2 -flexible with wire and ferrule mm 2x1,0x2,5 Protection degree to IEC/EN 60 947-1 All terminals are safe from finger-touch and touch by the back of the hand in acc. with VDE 0106, Part 100 Switching frequency up to 15 ops./h or 60 ops./h with 40% on load factor and the starting time not exceeding 1s Required fuses for short circuit protection (back up) see Technical data II Loads for accessories Auxiliary contact for front mounting, HKF AC15 24 V, 3.0 A 230 V, 1.5 A Auxiliary contact for front mounting, HKF DC13 24 V, 1.0 A 48/60 V, 0.7 A 110 V, 0.27 A Auxiliary and Signal Contact, HK + SK AC15 24 V, 6 A 230 V, 4 A 400 V, 3.0 A Auxiliary and Signal Contact, HK + SK DC13 24 V, 2.0 A 110 V, 0.5 A 220 V, 0.25 A 440 V, 0.1 A Electromagnet trips Response value set ex-works 9.6 ... 14.4 x In Undervoltage release Pick-up value % of U 85 C Drop-out value % of U 35 ... 75 C Power consumption Pick-up VA on request Hold VA on request 7MS 116 Dimension Drawings MS 116 with auxiliary switch HKF 1 mounted on the front Manual motor starter MS 116 with accessories in accordance with the adjacent caption Caption 1 Open circuit shunt release 2 Undervoltage release 3 Undervoltage release with pre-mating auxiliary switches 2 SV 4 Remote operating mechanism 6 Built-in auxiliary switches 1 NO + 1 NC, on MS 116 convertible from NC to NO and from NO to NC 7 Short-circuit pilot switch block 1 NO + 1 NC 8 Tripped pilot switch block (signal contact) 9 Auxiliary switches pluggable on front 10 Pilot switch for short-circuit and general tripping Housing IP 65 for MS 116 8