IND011SIP Hornet: Non-Isolated DC-DC Voltage Regulator Modules 12Vdc input 0.6Vdc to 5.5Vdc output 11W Max Power Vin+ Vout+ VIN VOUT MODULE Applications Cin Co Industrial Equipment TRIM Control Boards ON/OFF Test Equipment GND RTrim Electrical Features Mechanical Features 12V Input voltage with adequate Tolerance Small size: 10.4 mm x 13.5 mm x 8.1 mm (0.41 in x 0.53 in x 0.32 in) Output voltage programmable from 0.6Vdc to 5.5Vdc via external resistor Operating range: -40C to 85C ambient Remote On/Off for optional external control Fixe d s w itch in g fr e q u e n cy Output overcurrent protection (non-latching) Process and Safety ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 Recognized, DIN VDE 0868-1/A11:2017 (EN62368-1:2014/A11:2017) ISO** 9001 and ISO 14001 certified manufacturing facilities Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 Compliant to REACH Directive (EC) No 1907/2006 Compatible in a Pb-free or SnPb reflow environment. Suitable for aqueous clean. Suitable for conformal coating with dip and vapor deposition. Conformal coating can provide the protection to meet Salt Fog Test per IEC 60068-2-52 (Severity 3) and Mixed Gas Flow test per Telcordia GR-3108 Outdoor Levels. 3 year warranty. Output Output Device Code Input Voltage On/Off Logic Comcode Voltage Current (Max.) 1600102909A IND011SIP 9.6 14Vdc 0.6 5.5Vdc 2A Positive Thermal Performance Full rated output with natural convection up to 85C for all output voltages. 2.5 NC 2.0 1.5 1.0 0.6Vout to 5Vout 0.5 Current (A) vs. Temp( C) 0.0 45 55 65 75 85 May 12, 2021 2017 General Electric Company. All rights reserved. Page 1 Electrical Specifications Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 9.6 12 14 Vdc VO,set = 0.6 Vdc IIN,No load 20 mA Input No Load Current (VIN = 12.0Vdc, IO = 0, module enabled) VO,set = 5Vdc IIN,No load 48 mA External Capacitance, Ceramic ESR 1 m All CO, max 22 47* F Efficiency 12V , T =25C, I=12A, Vo=0.6 to 3.3Vdc 69.2(0.6V), 85.5(1.8V), 93.3(5V) % INDC A Switching Frequency All f 600 kHz sw Output Voltage (Over all line, load, and temperature All VO, set -3.0 +3.0 % VO, set conditions) On/Off Logic High (MODULE ON) Input High Voltage All VIH 3 14 Vdc On/ Off Logic Low (MODULE OFF) Input Low Voltage All VIL -0.3 0.3 Vdc *Additional External Capacitance possible using Tunable Loop Characteristic Curves o The following figures provide typical characteristics for the 2A Hornet at 25 C. Figure 1. Output Ripple Voltage (20MHz BW) for various output Figure 2. Typical Start-up using Input Voltage (Vin=12V, Vout = voltages and external caps 12Vin. Additional Decoupling cap of Vout, max, Iout = Iout, max) 0.1uF used on input and output side Trim Without an external resistor between Trim and GND pins, the output of the module will be 0.6Vdc. Rtrim for a desired output voltage, should be as per the following table. The formula in the last column helps determine Rtrim for other voltages. Vo (V) 0.6 0.9 1.0 1.2 1.5 1.8 2.5 3.3 5.0 12 Rtrim = k Rtrim (k) Open 40 30 20 13.3 10 6.316 4.4 2.727 (Vo 0.6 ) Safety Considerations For safety agency approval, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standards listed on the first page of this document. For the converter output to be considered meeting the requirements of safety extra-low voltage (SELV) or ES1, the input must meet SELV/ES1 requirements. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. An input fuse for the module is recommended. Due to the wide input voltage and output voltage ranges of the module, a 4A, 125Vdc fast acting fuse is recommended. May 12, 2021 2017 General Electric Company. All rights reserved. Page 2