IND033 Hornet: Non-Isolated DC-DC Voltage Regulator Modules 12Vdc input 0.8Vdc to 5.5Vdc output 33W Max Power Vout+ Vin+ VIN VOUT SENSE PGOOD MODULE Applications Co Cin Industrial Equipment TRIM ON/OFF Control Boards GND RTrim Test Equipment Electrical Features Mechanical Features 12V Input voltage with up to 20% Tolerance Small size: 12.2 mm x 12.2 mm x 7.25 mm (0.48 in x 0.48 in x 0.29 in) Output voltage programmable from 0.8Vdc to 5.5Vdc via external resistor Operating range: -40C to 105C ambient Remote On/Off for optional external control Operating shock to 40G per Mil Std. 810G, Power Good signal for external monitoring Method 516.4 Procedure I Operating vibration per Mil Std. 810G, Method Fixed switching frequency 514.5 Procedure I Output overcurrent protection (non-latching) Process and Safety Qualified for 1000h High Temperature Operating Bias, 1000h 85RH/85C Temperature, Humidity and Bias, 700 cycle -40 to 125C thermal cycling ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 Recognized, DIN VDE 0868-1/A11:2017 (EN62368-1:2014/A11:2017) ISO** 9001 and ISO 14001 certified manufacturing facilities Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 Compliant to REACH Directive (EC) No 1907/2006 Compatible in a Pb-free or SnPb reflow environment. Suitable for aqueous clean. Suitable for conformal coating with dip and vapor deposition. Conformal coating can provide the protection to meet Salt Fog Test per IEC 60068-2-52 (Severity 3) and Mixed Gas Flow test per Telcordia GR-3108 Outdoor Levels. 3 year warranty Output Output Device Code Input Voltage On/Off Logic Comcode Voltage Current (Max.) Negative 1600102898A IND033 9.6 14.4**Vdc 0.8 5.5Vdc 6A Thermal Performance Full rated output with natural convection up to 100C at 1.2Vout and up to 90C at 5Vout. Thermal curves for 1.2V, 1.8V and 5Vout below. 6.5 6.5 6.0 6.0 NC NC 1.2 Vout 1.8 Vout 5.5 0.5m/s 5.5 Current (A) vs. Temp ( C) 0.5m/s Current (A) vs. Temp ( C) (100LFM) (100LFM) 5.0 5.0 4.5 4.5 55 65 75 85 95 105 55 65 75 85 95 105 May 12, 2021 2017 General Electric Company. All rights reserved. Page 1 Electrical Specifications Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 9.6 12 14.4** Vdc IN Input No Load Current V = 5Vdc I 55 mA O,set IN,No load (VIN = 12.0Vdc, IO = 0, module enabled) External Capacitance, Ceramic ESR 1 m All C 10 22* F O, max Efficiency 12VINDC, TA=25C, I=12A, Vo=1.2 to 5Vdc 86(1.2V), 89(1.8V), 93(3.3V), 94(5V) % Switching Frequency All fsw 600 kHz Output Voltage (Over all line, load, and temperature All VO, set -3.0 +3.0 % VO, set conditions until end of life) On/Off Logic High (MODULE OFF) Input High Voltage All VIH 3.0 14.4 Vdc On/ Off Logic Low (MODULE ON) Input Low Voltage All VIL -0.2 0.4 Vdc PGOOD (Power Good) Signal Interface Open Drain, Vsupply 5VDC Overvoltage threshold for PGOOD 112.5 %V O, set Undervoltage threshold for PGOOD 87.5 %VO, set Pulldown resistance of PGOOD pin All 30 Sink current capability into PGOOD pin All 5 mA *Additional External Capacitance possible using Tunable Loop ** For 0.8Vout<1, do not exceed 12Vin. For 1Vout<1.2, do not exceed 13Vin. For Vout1.2, Input Voltage can be as high as 14.4V Characteristic Curves o The following figures provide typical characteristics for the IND033 Hornet at 25 C. 80 1x10uF Ext Cap 1x22uF Ext Cap 70 1x47uF Ext Cap 60 2x47uF Ext Cap 50 40 30 20 10 0 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 4 4.4 4.8 5.2 Output Voltage(Volts) Figure 1. Output Ripple Voltage (20MHz BW) for various output Figure 2. Typical Start-up using Input Voltage (Vin=12V, voltages and external caps 12Vin. Additional Decoupling cap of Vout = Vout, max, Iout = Iout, max) 0.1uF used on input and output side Trim Without an external resistor between Trim and GND pins, the output of the module will be 0.6Vdc. Rtrim for a desired output voltage, should be as per the following table. The formula in the last column helps determine Rtrim for other voltages. Vo (V) 0.9 1.2 1.5 1.8 2.5 3.3 5.0 12 Rtrim = k Rtrim (k) 40 20 13.3 10 6.316 4.4 2.727 (Vo 0.6 ) Safety Considerations For safety agency approval, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standards listed on the first page of this document. For the converter output to be considered meeting the requirements of safety extra-low voltage (SELV) or ES1, the input must meet SELV/ES1 requirements. The power module has May 12, 2021 2017 General Electric Company. All rights reserved. Page 2 Ripple (mVp-p)