Preliminary Data Sheet GE Compact Power Line Shelves RS485 type shelves for the GP100 rectifier Model: J2014001L4xx Features L401 Mounts into standard 19 EIA-310-D racks L401C Terminal block AC connections -48Vdc output Adjustable mounting ears Supports hot-swapping of modules Mechanical latching slots L402 RS485 based GE Galaxy Protocol Emergency Power OFF pin (Interlock) Passes Zone 4 earthquake requirements CUR* recognized CB report CE Mark L422 Shock & Vibration: Meets IPC 9562 Class II Description This Preliminary Data Sheet documents the capabilities of shelves supporting the RS485 based interface. These shelves are designed for use with the GP100H3R48RE and associated family of rectifiers. GE offers a comprehensive set of supporting components. A system controller is normally inserted into the first shelf. Normally, the system controller communicates using the GE Galaxy Protocol. The purpose of the controller is to maintain the functionality of the power system and inform/be-guided- by remote management controllers. Further information on the capabilities of these turn- key systems can be obtained from your GE Sales Representative * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. This product is intended for integration into end-user equipment. All CE marking procedures of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards May 25, 2016 2016 General Electric Company. All rights reserved. Preliminary Data Sheet GE Compact Power Line Shelves RS485 type shelves for the GP100 rectifier Model: J2014001L4xx Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Symbol Min Max Unit Input Voltage: Continuous VIN 0 600 Vac 1 Operating Ambient Temperature TA -10 75 C Storage Temperature Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) 2087 VAC Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions. INPUT Parameter Symbol Min Typ Max Unit Operational Range V 320 380/480 530 V IN AC F IN Frequency Range 47 50/60 63 Hz I IN 15 A AC Input Current, (3 - all phases operational) AC Recommended AC Breaker Size 480VAC 10 AAC 380V 15 AC Leakage Current (per , 530VAC, 60Hz) IIN 2.5 3.5 mA Isolation (per EN60950) Input Output 3000 V AC V Input-Chassis/Signals 2000 V AC MAIN OUTPUT Parameter Symbol Min Typ Max Unit Output Power W 0 - 12,000 W Max output current I 250 A OUT DC Isolation Output/frame other circuits V 100 VDC General Specifications Parameter Min Typ Max Units Notes Full load, 25C MTBF per SR232 Reliability protection Reliability TBD Hrs for electronic equipment, issue 2, method I, case III, Unpacked Weight Kgs/Lbs Packed Weight TBD Kgs/Lbs Safety/Standards Compliance Safety Standards UL60950-1, CAN/CSA C22.2 No 60950-1, EN60950-1 Certification Marks CE mark, UL Recognized (Canada and U.S.) 1 See the derating guidelines published in the rectifier data sheet May 25, 2016 2016 General Electric Company. All rights reserved. Page 2