Data Sheet GE Compact Power Line Shelves 2 Dual I C Shelves for the GP100 rectifier Model: J2014001L601 Features Mounts into standard 19 EIA-310-D racks Isolated output feed may be grounded at either polarity +5V standby power isolated from the main output Adjustable mounting ears for flush or set back positions. Supports hot-swapping of modules Accommodates mechanical latching into the slot Communicates via PMBus compliant dual, redundant 2 I C Designed to pass Zone 4 earthquake requirements when integrated into a seismic rated system or rack CUR* recognized CB report CE Mark Shock & Vibration: Meets IPC 9562 Class II standards Purpose The J2014001L601 shelf provides the supporting enclosure for the GP100H3 family of 6000W Global Platform rectifiers supporting dual- 2 redundant I C communications. Designed to be mounted into standard 19 enclosures, the shelf comes with adjustable mounting ears that provide either flush-front or further-forward positioned arrangements. The rugged enclosure passes Zone 4 earthquake rating. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. This product is intended for integration into end-user equipment. All CE marking procedures of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards November 2, 2017 2017 General Electric Company. All rights reserved. Data Sheet GE Compact Power Line Shelves 2 Dual I C shelves for the GP100 rectifier Model: J2014001L601 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Symbol Min Max Unit Input Voltage: Continuous VIN 0 600 Vac 1 Operating Ambient Temperature TA -10 75 C Storage Temperature Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) 2087 VAC Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions. INPUT Parameter Symbol Min Typ Max Unit Operational Range V 320 380/480 530 V IN AC F IN Frequency Range 47 50/60 63 Hz I IN AC Input Current, (3 - all phases operational) 15 A AC Recommended AC Breaker Size 480V 10 AC A AC 380VAC 15 I 2.5 3.5 mA Leakage Current (per , 530VAC, 60Hz) IN Isolation (per EN60950) Input Output 3000 V AC V Input-Chassis/Signals 2000 V AC MAIN OUTPUT Parameter Symbol Min Typ Max Unit Output Power W 0 - 12,000 W Factory set default set point V 54/48 VDC Max output current I 250 ADC OUT Isolation Output/frame other circuits V 100 V DC AUXILIARY OUTPUT Parameter Symbol Min Typ Max Unit Set point V 5.0 V OUT DC Output current I 0 4 A OUT DC V 50 VDC Isolation Output/Frame Output/Main output V 50 V DC 1 See the derating guidelines published in the rectifier data sheet November 2, 2017 2017 General Electric Company. All rights reserved. Page 2