Preliminary Data Sheet GE Compact Power Line Shelves RS485 shelf for the CP3500 rectifier Model: J2014004 Features Mounts into standard 19 EIA-310-D racks Single main output feeder either grounded or isolated +5V standby power isolated from main output Adjustable mounting ears for flush or set back positions. Supports hot-swapping of modules Accommodates mechanical latching into the slot Communicates via RS485 using the Galaxy Protocol LAN/Ethernet remote connectivity Daisy chained RJ45 connections may configure up to 20 shelves of rectifiers in parallel Passes Zone 4 earthquake requirements CUR* recognized TUV certified CE Mark Shock & Vibration: Meets IPC 9562 Class II standards Description The 1U (1.75) high family of J2014004 type shelves are designed to mount into 19-inch wide frames providing up to 14kW of 54V output power. There are four slots for modules. These shelves are designed for the CP3500AC54TE rectifier. The shelves are parallelable. A slide switch identifies the first shelf. Subsequent shelf addressing is automatically configured internally. These shelves are designed for RS485 communications. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment. All CE marking procedures of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards March 7, 2016 2014 General Electric Company. All rights reserved. Preliminary Data Sheet GE Compact Power Line Shelves RS485 shelf for the CP3500 rectifier Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Symbol Min Max Unit Input Voltage: Continuous VIN 0 300 V ac 1 Operating Ambient Temperature TA -40 65 C Storage Temperature Tstg -40 85 C I/O Isolation voltage to Frame (100% factory Hi-Pot tested) 2250 Vac Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions. INPUT Parameter Symbol Min Typ Max Unit Operational Range VIN 85 110/230 300 VAC F IN Frequency Range 47 50/60 63 Hz I IN AC Input Current, per module 20 AAC MAIN OUTPUT Parameter Symbol Min Typ Max Unit Output Power V > 200V 0 - 14,000 W in AC W Vin 140VAC 0 - 6,000 W Max output current I 270 ADC OUT 2 Isolation Output/frame other circuits non-POE 100 V V DC POE 2250 AUXILIARY OUTPUT Parameter Symbol Min Typ Max Unit Set point V 5.0 V OUT DC Overall regulation (load, temperature, aging) V -10 +5 % OUT Output current IOUT 0 8 ADC V 50 VDC Isolation Output/Frame Output/Main output non-POE 50 V VDC POE 2250 The auxiliary output should be accessible to the user via a two position panel mounted connector capable of carrying 9A of current. The 5V and ground symbol should be located near the connector to identify the two pins. 1 See the derating guidelines published in the rectifier data sheet 2 The standard CP3500AC54TEZ currently in development is not designed for POE . March 7, 2016 2014 General Electric Company. All rights reserved. Page 2