Data Sheet GE KBVW006A0B Series (Sixteenth-Brick) DC-DC Converter Power Modules 36 75Vdc Input 12.0Vdc Output 6A Output Current * Features BARRACUDA SERIES Wide input voltage range: 36-75 V dc Monotonic startup into prebiased load Output Voltage adjust: 80% to 110% of V o,nom Remote sense Constant switching frequency Positive remote On/Off logic Input under/over voltage protection Output overcurrent and overvoltage protection Over-temperature protection RoHS Compliant Industry standard, DOSA compliant footprint 33.0 mm x 22.9 mm x 9.3 mm (1.30 x 0.90 x 0.366 in) Low profile height and reduced component skyline Applications High efficiency: 91.0% Distributed Power Architectures Wide operating temperature range (-40C to 85C) Wireless Networks Compliant to RoHS Directive 2011/65/EU and amended Access and Optical Network Equipment Directive (EU) 2015/863 (-Z versions ) Industrial Equipment Compliant to REACH Directive (EC) No 1907/2006 Compliant to IPC-9592A (May 2010), Category 2, Class II ANSI/UL 62368-1 and CAN/CSA C22.2 No. 62368-1 Options Recognized, DIN VDE 0868-1/A11:2017 (EN62368- 1:2014/A11:2017 Negative Remote On/Off logic (preferred) CE mark meets 2014/35/EU directive Over current/Over temperature/Over voltage protections (Auto-restart) (preferred) Meets the voltage and current requirements for ETSI 300- 132-2 and complies with and licensed for Basic insulation Surface Mount version (-S) rating Heat Plate version (-H) 2250 Vdc Isolation tested in compliance with IEEE 802.3 For additional options, see Table 2 (Device Options) under PoE standards Ordering Information section. ** ISO 9001 and ISO 14001 certified manufacturing facilities Description The KBVW006A0B, Sixteenth-brick low-height power module is an isolated dc-dc converters that can deliver up to 6A of output current and provide a precisely regulated output voltage of 12.0V over a wide range of input voltages (VIN = 36 - 75Vdc). The modules achieve typical full load efficiency of 91%. The open frame modules construction, available in both surface-mount and through-hole packaging, enable designers to develop cost and space efficient solutions. * Trademark of General Electric Company UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment. All of the required procedures of end-use equipment should be followed. IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards April 28, 2021 2014 General Electric Company. All rights reserved. Data Sheet GE KBVW006A0B Series Sixteenth-Brick Power Modules 36 75Vdc Input 12.0Vdc Output 6A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All V -0.3 80 V IN dc Transient, operational (100 ms) All V -0.3 100 V IN,trans dc Operating Ambient Temperature All TA -40 85 C (see Thermal Considerations section) Storage Temperature All Tstg -55 125 C I/O Isolation voltage (100% factory Hi-Pot tested) All 2250 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 36 48 75 Vdc Maximum Input Current All IIN,max 2.8 Adc (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current All IIN,No load 45 mA (V = 48V, I = 0, module enabled) IN O Input Stand-by Current All I 8 10 mA IN,stand-by (VIN = 48V, module disabled) 2 2 Inrush Transient All I t 0.5 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance VIN, min to VIN, max, IO= IOmax All 30 mAp-p See Test configuration section) Input Ripple Rejection (120Hz) All 50 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. April 28, 2021 2014 General Electric Company. All rights reserved. Page 2