Data Sheet GE KHHD002A5B Hammerhead Series DC-DC Converter Power Modules 18-75Vdc Input 12Vdc, 2.5A Output Features Compliant to REACH Directive (EC) No 1907/2006 Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 (-Z versions) Ultra-wide Input Voltage Range, 18V to 75V dc dc No minimum load High efficiency 90% at full load (V =48V ) IN dc Constant switching frequency Low output ripple and noise RoHS Compliant Small Size and low profile, follows DOSA standard 1/16th footprint 33.0 mm x 22.9 mm x 9.3 mm (1.30 in x 0.9 in x 0.37 in) Applications Surface mount (SMT) or Through hole (TH) Wireless Networks Reflow process compliant, both SMT and TH versions Hybrid power architectures Positive Remote On/Off logic Optical and Access Network Equipment Output overcurrent/voltage protection (hiccup) Enterprise Networks including Power over Ethernet (PoE) Over-temperature protection Industrial markets Output Voltage adjust: 80% to 110% of V o,nom Wide operating temperature range (-40C to 85C) Options ANSI/UL* 62368-1 and CAN/CSA C22.2 No. 62368-1 Negative Remote On/Off logic (preferred) Recognized, DIN VDE 0868-1/A11:2017 (EN62368- 1:2014/A11:2017) Surface Mount/Tape and Reel (-SR Suffix) CE mark meets 2014/35/EU directive Auto-restart Over current/Over voltage protections (preferred) Meets the voltage and current requirements for ETSI 300- 132-2 and complies with and licensed for Basic insulation Shorter through hole pin trim rating 2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE standards ISO** 9001 and ISO 14001 certified manufacturing facilities Description th The KHHD002A5B series power modules are isolated DOSA compliant 1/16 brick dc-dc converters that operate over an ultra-wide input voltage range of 18 Vdc -75Vdc and provide a single precisely regulated output voltage at 12Vdc. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency of 90% typical at full load. Built-in filtering for both input and output minimizes the need for external filtering. The module is fully self-protected with output over-current and over-voltage, over-temperature and input under voltage shutdown control. Optional features include negative or positive on/off logic and SMT connections * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment. All of the required procedures of end-use equipment should be followed. IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards. March 18, 2021 2012 General Electric Corporation. All rights reserved. Page 1 Data Sheet GE KHHD002A5B Hammerhead Series DC-DC Converter Power Modules 18-75Vdc Input 12Vdc, 2.5A Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage (Continuous) All V -0.3 80 Vdc IN Transient (100ms) All V -0.3 100 Vdc IN, trans Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Altitude* All 4000 m I/O Isolation Voltage (100% factory Hi-Pot tested) All 2250 Vdc * For higher altitude applications, contact your GE Sales Representative for alternative conditions of use. Electrical Specifications Unless otherwise indicated, specifications apply at V = 48V , resistive load, and T = 25C conditions. IN dc A Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 18 24/48 75 Vdc Input No Load Current All I 50 mA IN,No load (VIN = 48Vdc IO = 0A, module enabled) Input Stand-by Current All I 8 mA IN,stand-by (V = 24 to 48V , module disabled) IN dc Maximum Input Current (V =18V , I = I ) All I 2.2 A IN dc O O,MAX IN, MAX dc 2 2 Inrush Transient All I t 0.05 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance V =0V to 75V , I = I see All 25 mA IN dc O Omax p-p Test configuration section) Input Ripple Rejection (120Hz) All 60 dB EMC, EN55032 See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of complex power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. March 18, 2021 2012 General Electric Corporation. All rights reserved. Page 2