Data Sheet GE KW010/015/020/025 Series Power Modules 36 75Vdc Input 1.2 to 5.0Vdc Output 10 to 25A Output current RoHS Compliant Features Compliant to RoHS EU Directive 2011/65/EU (Z versions) Compliant to RoHS EU Directive 2011/65/EU under exemption 7b (Lead solder exemption). Exemption 7b will expire after June 1, 2016 at which time this produc twill no longer be RoHS compliant (non-Z versions) Delivers up to 25A output current 5V(10A), 3.3V(15A), 2.5V(20A), 1.8V-1.2V(25A) Representative Photo, actual product may vary. High efficiency 91% at 3.3V full load Small size and low profile: Applications 33.0 mm x 22.9 mm x 8.5 mm Distributed power architectures (1.30 in x 0.9 in x 0.335 in) Wireless networks Industry standard DOSA footprint Access and optical network Equipment -20% to +10% output voltage adjustment trim Enterprise Networks Remote On/Off Latest generation ICs (DSP, FPGA, ASIC) and Remote Sense Microprocessor powered applications No reverse current during output shutdown Over temperature protection (latching) Options Output overcurrent/overvoltage protection (latching) Negative Remote On/Off logic Wide operating temperature range (-40C to 85C) Surface Mount (Tape and Reel, -SR Suffix) Meets the voltage isolation requirements for Over current/Over temperature/Over voltage ETSI 300-132-2 and complies with and is licensed for protections (auto-restart) Basic Insulation rating per EN60950-1 Shorter lead trim UL* 60950-1Recognized, CSA C22.2 No. 60950-1-03 rd Certified, and VDE 0805 (IEC60950 3 Edition) Licensed CE mark meets 2006/95/EC directive ISO** 9001 and ISO 14001 certified manufacturing facilities Description The KW (Sixteenth-brick) series power modules are isolated dc-dc converters that operate over a wide input voltage range of 36 to 75Vdc and provide a single precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, typical efficiency of 91% for 3.3V/15A. These open frame modules are available either in surface-mount (-SR) or in through-hole (TH) form. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-use equipment. All of the required procedures of end-use equipment should be followed ** ISO is a registered trademark of the International Organization of Standards October 5, 2015 2012 General Electric Company. All rights reserved. Data Sheet GE KW010/015/020/025 Series Power Modules 36 75Vdc Input 1.2 to 5.0Vdc Output 10 to 25A Output current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All V -0.3 80 Vdc IN Transient (100 ms) All V -0.3 100 Vdc IN,trans Operating Ambient Temperature All TA -40 85 C (see Thermal Considerations section) Storage Temperature All Tstg -55 125 C I/O Isolation voltage (100% Factory Hi-Pot tested) All 1500 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 36 48 75 Vdc Maximum Input Current All IIN,max 1.7 2.0 Adc (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current All I 55 mA IN,No load (VIN = VIN, nom, IO = 0, module enabled) Input Stand-by Current All I 5 7 mA IN,stand-by (VIN = VIN, nom, module disabled) 2 2 Inrush Transient All It 0.1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1 H source impedance V to V All 30 mA IN, min IN, p-p I = I See Test configuration section) max, O Omax Input Ripple Rejection (120Hz) All 50 60 100 dB EMC, EN55022 See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. October 5, 2015 2012 General Electric Company. All rights reserved. Page 2